Outside Air Hookup - England's Stove Works 25-IP Installation & Operation Manual

Imperial pellet stove
Hide thumbs Also See for 25-IP:
Table of Contents

Advertisement

 The use of outside combustion air is mandatory on this pellet stove.
 The outside air connection pipe protrudes from the lower rear center of the stove;
use the included outside air kit to attach your stove to outside combustion air.
Instructions and all the parts needed to make the outside air connection to your
pellet stove are included with the outside air kit.
 If it is not feasible to use the included outside air hookup kit in your stove
installation, other materials may be used, provided the following rules are followed:
 The pipe used for outside air hookup must be metal, with a minimum
thickness of .0209 in. (25 gauge mild steel) or greater and an inside diameter
of approximately 2.0 in.
 All pipe joints and connections should be sealed with pipe clamps or other
mechanical means, to insure a leak free outside air connection.
 Long runs of pipe and excessive elbows for outside air should be avoided. Due
to frictional resistance in pipe, any excessive outside air piping can result in
poor stove performance.
 A screen or other protection device must be fitted over the outside air
termination point to prevent rain, debris and nuisance animals from entering
the piping system.
 Increase the outside air pipe size to 3.0 in. diameter pipe if the outside air
connection is more than 6 ft. in length, more than two (2) elbows are used or if
the stove is installed in a basement.
 The outside air connection system should be inspected at least annually to be certain
it is free from blockage.
2. Enclosed space such as an attic, garage or crawl space.
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
OUTSIDE AIR HOOK-UP
Caution
NEVER draw outside combustion air from:
1. Wall, floor or ceiling cavity.
QUESTIONS.
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

55-shpip55-trpip25-ips55-shpips55-trpips

Table of Contents