INSTALLATION & OPERATION MANUAL
MODEL NUMBERS:
Thank you for purchasing this product from a fine line of heating equipment.
We wish you many years of safe heating pleasure with your new heating appliance.
IMPORTANT: IF YOU HAVE A PROBLEM WITH THIS UNIT DO NOT RETURN IT TO
THE DEALER. CONTACT TECHNICAL SUPPORT @ 1-800-245-6489.
Please Note the Following Precautionary Statements:
THIS PELLET INSERT IS NOT APPROVED FOR MOBILE HOME INSTALLATION.
FOR MASONRY FIREPLACE INSTALLATION ONLY!
NOTE: WE DO NOT RECOMMEND PELLET STOVES AS YOUR ONLY SOURCE OF HEAT.
England's Stove Works highly recommends the use of smoke detectors and Carbon
Monoxide detectors with any hearth product, including this unit. Follow all
manufacturer's instructions when using smoke or Carbon Monoxide detectors.
CAUTION: Please read this entire manual before installation and use of this pellet
fuel burning room heater.
Keep children, furniture, fixtures, and all combustible materials away from
any heating appliance. Refer to this owner's manual for all clearances to
combustible materials.
WARNING: USE OF OUTSIDE AIR IS MANDATORY WITH THIS UNIT.
DO NOT OPERATE UNIT WITH HOPPER OPEN. LID MUST BE SHUT AND TIGHTLY SECURED.
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY
INJURY OR EVEN DEATH. FOR YOUR SAFETY AND PROTECTION, FOLLOW ALL THE
INSTALLATION INSTRUCTIONS. CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS FOR
RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS (INCLUDING PERMITS) IN
YOUR AREA.
Questions? Need Parts or Accessories?
IMPORTANT NOTICE: This unit must be properly installed to prevent the possibility of a
house fire or "smoke-back." The instructions must be strictly adhered to.
Do not use makeshift methods or material which may compromise the installation.
Your unit requires periodic maintenance and cleaning (refer to manual). Failure to maintain
your unit may lead to a variety of problems, including but not limited to smoke spillage into the
home.
England's will not be liable for consequential or indirect damages to property or
persons resulting from the use of this product.
25-PI
Save These Instructions.
DO NOT OPERATE WITH DOOR OPEN.
SAFETY NOTICE
55-SHP20
55-TRP20
www.englanderstoves.com
REV. 1/07

Advertisement

Table of Contents
loading

Summary of Contents for England's Stove Works 25-PI

  • Page 1 FOR MASONRY FIREPLACE INSTALLATION ONLY! NOTE: WE DO NOT RECOMMEND PELLET STOVES AS YOUR ONLY SOURCE OF HEAT. England’s Stove Works highly recommends the use of smoke detectors and Carbon Monoxide detectors with any hearth product, including this unit. Follow all manufacturer’s instructions when using smoke or Carbon Monoxide detectors.
  • Page 2 A letter from our Technical Support department: Thank you for purchasing this fine product from England’s Stove Works! England's Stove Works was started, and is still owned by, a family that believes strongly in a "Do It Yourself" spirit – that’s one reason you found this product at your favorite “Do It Yourself”...
  • Page 3 Central Furnace. If you install your stove in the same room as the Cold Air Return from your home’s Central Furnace, you must place your stove at least 20 feet (20’) from the Cold Air Return. We recommend you open an outside window slightly, and never close the door that leads from this room to the rest of your home.
  • Page 4 Read and comply with the instructions in this manual. This unit should be tested (dry run) before loading pellets for 20 minutes. The stove should automatically shut itself off after the 20-minute dry run.
  • Page 5: Unit Preparation

    It is important to note that this stove is equipped with a dual auger system. The top auger runs intermittently and drops pellets to the bottom auger; the bottom auger runs constantly and simply pushes the pellets forward to the burn pot.
  • Page 6 Let the bottom of the plate rest on the firebox, and then push the bottom of the plate flush against the back wall of the firebox. At this point, the plate will lean forward (toward the front of the stove) slightly, and will come in contact with the front of the stove above the door.
  • Page 7: Flue System

    Call Technical Support (800-245-6489) if you have questions about your hook-up or if your unit will not operate. FLUE SYSTEM Pellet Vent Pipe Mobile Home Installation caused by the malfunction of a stove due to improper venting or installation. England’s Stove Works ” I.D.
  • Page 8: Installation Into A Masonry Fireplace

    INSTALLATION INTO A MASONRY FIREPLACE Measure your hearth to be sure it is large enough to accept the unit. The hearth should be twelve inches (12”) from the face of the fireplace to the edge and at least thirty-six inches (36”) wide. The unit requires eighteen inches (18”) of protection in front of the firebox.
  • Page 9: Floor And Wall Protection

    (6”) on both sides of the stove. From the sides of this stove only six inches (6”) of clearance is required to paneling, wallpaper or drywall. Above the unit, a clearance of 24” is required to an unprotected, combustible mantle.
  • Page 10: Start-Up Procedure

    Do not burn trash (paper bags, etc.) in this unit. This stove has an induced draft system and is designed to operate continuously, as frequent shutdown is not required. The digital control board operates the unit with a time delay-relay system;...
  • Page 11: Shutdown Procedure

    The red light will then shut off and the entire stove will be shut down. The hotter the unit is operating, the longer it will take for the stove to complete the Shut-Down cycle.
  • Page 12: Daily Operation

    If the Combustion (exhaust) Blower should fail on this unit, a Vacuum Shut-Down Switch will automatically stop the stove. This will shut your unit completely off, and there will be an “E-1” code in the Heat Range and Blower Speed windows on the Control Board.
  • Page 13: Ash Removal And Disposal

    Press the “OFF” touch pad and allow the stove to burn for five (5) minutes prior to opening the door. A long-handled screwdriver or long-handled putty knife can be used to scrape off any build-up or crust in the burn pot area.
  • Page 14 The stove and the flue system should be given a complete cleaning at the end of the heating season. Remove the burn pot assembly, clean it thoroughly, and re-install it (refer to Illustration 6);...
  • Page 15: Maintenance

    The Convection (room air) Blower (Part # PU-4C447) is located on the left side of the unit and can be removed by disconnecting the power leads and removing the four mounting screws. Once this is done, the blower will slide out of the stove. This procedure can be reversed to install a new blower.
  • Page 16 Next, remove the screws that hold the blower to the steel exhaust tube and slide the blower from the stove. Note: There is a Combustion Motor Gasket (Part PU-CMG), which allows you to remove the motor from the Combustion Blower housing, clean your stove, and replace the motor and gasket without having to remove the entire Combustion Blower.
  • Page 17 This part can be removed from the unit by loosening the two outside screws and pulling the board back to the inside of the stove. The rear access panel should be removed prior to removing the control board. A 6-amp “quick-blow” fuse (Part # PU-CBF6) is used on this Control Board.
  • Page 18 Disconnect Power Before Servicing Unit. If the unit or chimney connector pipe “glows” red (or white), the stove is over-fired. This condition could cause a house or chimney fire. Do not operate your unit too hot, or over- firing may result.
  • Page 19: Accessory Items

    The spring clip will hold well if it is placed on the top edge of the trim before placing the trim in the window of the stove. Place the top edge with the clip into the window opening, then push the bottom edge of the trim flush with the window.
  • Page 20 REPLACEMENT PARTS, ACCESSORIES AND OPTIONS AC-GGK Glass Gasket Kit (gasket only, no glass) AC-DGKC Door Gasket Kit (#2 on diagram) AC-114 Brass Louvers (#26 on diagram) (2001 and later Models; for earlier models call 800-245-6489 for AC-112 louvers) AC-114BN Nickel Louvers (#26 on diagram) AC-G9 9”...
  • Page 21 Pellet Stove – Exploded View Diagram Illustration 6...
  • Page 22 Attach the side pieces to the top piece using the hardware provided. Remove the six (6) sheet metal mounting screws from the stove. Position the back plate over the stove and align the plate to the screw holes on the unit. Install the six (6) mounting screws and tighten.
  • Page 23: Troubleshooting Guide

    1. Remove auger and clean 2. Re-align auger 1. Check blower for material 2. Check impeller blower screw 1. Check stove connection 2. Check settings; always start unit on “5” to “9”setting 3. Check igniter for buildup 1. Check for flue blockage (nests, rodents, excess soot, etc.)
  • Page 24 Have this information on hand if you phone the factory or your dealer regarding this product. Retain for your files: Model Number __________________________ Date of Purchase ________________________ Date of Manufacture _________________ Serial #_____________________ FROM THE DATE OF PURCHASE TO THE ORIGINAL OWNER The manufacturer extends the following warranties: Five Year Period: 1.
  • Page 25: Dealer Information

    WARRANTY REGISTRATION for England’s Stove Works Purchased by (Name) ______________________________________________ Address _________________________________________________________ City ________________________ State __________ Zip _________________ Telephone _______________________________________________________ Email Address ___________________________________________________ Purchased From (Dealer) ___________________________________________ Address _________________________________________________________ City ________________________ State __________ Zip _________________ (Please be sure to refer to sticker on back of manual or box to complete this section)

This manual is also suitable for:

55-shp2055-trp2025-pi-1

Table of Contents