7 - 20 MC909X Integrator Guide
IPL Errors (Continued)
Table 7-4
Error Text
Partition is not valid on
this device
Wrong destination code
File type does not
support IPL Auto Select
Non-contiguous record
found
Timed Out - No data
Fail: Buffer Overrun
Partition Table not Valid
Invalid file format

Creating a Splash Screen

The source bitmap files used to create the default splash screens for the mobile computer are supplied with the
DCP for MC9090c50. These files can be modified using any of the standard windows image editors, allowing
customization for particular customers.
To create a custom splash screen, perform the following steps:
For mobile computers with monochrome screens, open the Splashmono.bmp file supplied with the DCP for
1.
MC9090c50 using an image editor.
For mobile computers with color screens, open the Splashcolor.bmp file supplied with the DCP for
2.
MC9090c50 using an image editor.
Modify the bitmap file and save.
3.
Create a splash partition using the steps shown in the
4.

Splash Screen Format

If the default files are not used to create the new splash screens, be sure to preserve the image format. The
formats are as follows:
Error Number
-27
The downloaded file specifies a partition entry that does not exist on
the device. Only download files that are valid for this device, or
change the partition table so that the new file is valid on the device.
-28
A specific partition was chosen from the Main Menu (not Auto
Select) but the file selected for download was for another partition.
Ensure that the partition selected from the Main Menu matches the
file selected for download.
-29
Monitor, Power Micro and Partition Table cannot be loaded with
Auto Select. Select the appropriate area, and try again.
-30
A Symbol HEX file download was attempted but the HEX file is
invalid. Ensure the file is in Symbol HEX file format.
-31
IPL was waiting for data from the source device but timed out
before receiving any. Check the source device connectivity and
retry.
-32
The serial port device could not keep up with incoming data. Retry
the serial download with a lower baud rate.
-33
The size of flash memory is different than that described in the
partition table. Retry the download with the correct partition table
file.
-34
The file format is invalid. Only Symbol HEX files are supported by
IPL.
Probable Cause