V Remove the rear boiler top panel [2].
V Remove the thermal insulation [1].
V Undo the quick-release catches [1] for the cleaning
access cover [2].
V Remove the cleaning access cover [2] and gasket from
the heat exchanger system.
Do not remove the strap around the bottom
of the secondary condensing heat exchanger
on the GB125/30 and 35 unless instructed
by a technician.