Conditions for operation

Maintaining the specified operating conditions will enable
the boiler to provide a high level of reliability and long serv-
ice life. Some details relate only to operation with Buderus
Logamatic control panels.
Caution: Risk of system damage if operating
conditions are not maintained.
Extreme divergence from the stated condi-
tions may cause irreversible damage to indi-
vidual components of the boiler as a whole.
V The information on the rating plate is defin-
itive.
2.7.1

General operating conditions

Min. boiler water
temperature
In combination with Logamatic control for variable low-temperature operating modes, such as Logamatic 2107
no requirements operating
Automatically by Logamatic controls not required but recommended with
temperatures are ensured by
2)
the Logamatic controls
Tab. 4 General operating conditions
1) A heating circuit with a mixer improves controllability and is specifically recommended for systems with several heating circuits.
2) If heating zones or a boiler circuit actuator cannot be regulated via the control device (for example pump logic), an operating temperature of
122 °F must be reached within 10 min of switching the burner ON by restricting the water volume flow.
Logano GB125 BE US/CA - Technical specifications are subject to change without prior notice.
Unit
inch
inch
inch
inch
inch
inch
lbs
Operating conditions
Operating interruption
(complete boiler shutdown)
GB125/22 BE
GB125/30 BE
37 1/2"
42 3/8"
25 3/4"
30 ½"
16"
20 ½"
10 5/8"
2 1/3"
16 1/8"
20 7/8"
423
503
Heating circuit with
1)
heating circuit mixer
low-temperature heating system
design 130/113 °F
Required with:
– Underfloor radiant heating systems
– Systems with large water capacity:
> 115 gal/MBH
(1 MBH = 100,000 Btu/hr)
2
Product description
GB125/35 BE
42 3/8"
30 ½"
20 ½"
20 7/8"
503
Min. return temperature
No requirements
11