10.2.3 TSC quick washing (Fig.25)
If enabled, at the programmed interval the display will
show the message to carry out TSC quick washing
and both leds of TSC keys will flash.
Press one of the two keys to carry out quick washing
(steam dispensing for approx. 3 sec.)
10.2.4. Cleaning TSC (Fig.26)
● Clean the TSC nozzle frequently with a sponge or
damp cloth. Make sure to clean the lower parts.
● Periodically use the cleaning tool included to clean
the TSC air pipe.
After this operation, push "Latte" button for 2-3
seconds.
10.3. Periodical maintenance
Have been fitted with economizers which do not
draw water from the boiler to make hot water, the
water in the boiler need only to be renewed from
time to time.
10.3.1. Renewal of water in the boiler
(Fig.27)
To be carried out only by qualified personnel.
● Turn off the machine and wait for the pressure in
the boiler to diminish (gauge needl on "0").
● Insert a rubber hose into the hose-end fitting (3)
(Fig.27)
● Use the wrench (1) to immobilize the fitting (2) and
loosen the hose-end fitting (3).
● Allow the water to flow out completely; then, close
the fitting (3) and remove the rubber hose.
● Refill the boiler (paragraph 7.3.).

11. STOPPING THE MACHINE

A - Temporary stop
● Carry out cleaning and maintenance operations.
● Wind up the cable and fasten it to the machine
with sticky tape.
● Cover the machine and place it in a dry room. Do
not leave it exposed to atmospheric agents and
do not allow it to be touched by children or unift
persons.
To disconnect from the main power supply, consult
qualified personnel.
B - Definitive stop
● Besides carrying out the operations necessary for
a temporary stop, cut off the cable, pack the ma-
chine in cardboard, polystyrene or other packing
material and consign it to firms authorized for its
disposal or to second-hand goods dealers.
66
12. PROBLEMS AND REMEDIES
Check operations to be carried out by the
user with the plug disconnected.
For any type of problem or inconvenience not
specifically indicated, disconnect the plug and
contact our service centre without attempting
any direct repairs.
A) The machine does not start:
- check that the plug is connected;
- In case of power failure wait for the power to return
and check if the earth leakage protection circuit
breaker or the main switch is on;
- check the condition of the plug and the supply
cable; if damaged have them replaced by qualified
personnel.
B) There is water under the machine:
- check that the drainage tray is not obstructed.
C) Slow dispensing:
- check that the filters and delivery heads are
clean;
- check that the coffee is not too finely ground.
D) Irregular steam delivery:
- check that the nozzles are not obstructed.