10
USB / S / RE
CLASSE 10 USB / S / RE
Manuale per il tecnico
Manuel destiné au technicien
Handbuch für den Techniker
Technician's Manual
Manual para el tecnico
Manual para o técnico

Advertisement

Table of Contents
loading

Summary of Contents for Rancilio CLASSE 10 USB

  • Page 1 USB / S / RE CLASSE 10 USB / S / RE Manuale per il tecnico Manuel destiné au technicien Handbuch für den Techniker Technician’s Manual Manual para el tecnico Manual para o técnico...
  • Page 2 Gli interventi e le procedure di programmazione indicati in questo manuale, sono di The interventions and the programming procedures described in this manual may only esclusiva pertinenza del tecnico installatore. be carried out by the technician/installer. Ce symbole indique les opérations et les procédures de programmation devant être faites Las intervenciones y los procedimientos de programación indicados en este manual, están exclusivement par un technicien installateur.
  • Page 3 ITALIANO -12 EN ENGLISH CONTENTS 1. making coffee ..........34 FR FRANCAIS 1-22 1.1 Number of dispensers 1.2 Operating cycle 2. Dispensing steam with the iSteam SYSTEm 34 DE DEUTSCH 2-2 2.1 Renewal the millk nozzle 3. Button panels ..........34 .1 Coffee button panel EN ENGLISH 33-42 .2 Function . Programming panel .4 Washing ES ESPAÑOL 4-52 .4.1 Washing of the coffee groups .4.2 Cleaning iSteam .5 Reset PT PORTUGUêS 5-42 .6 The timer button 4. Installation menu .
  • Page 4 mAKING cOffEE  Install the large nozzle (identified by 2 notches) to increase the quantity of whipped milk. 1.1 Number of Dispensers Note: iSteam nozzles are different to those utilised The coffee maker is equipped with 4 coffee dispen- for the TSC sers with programmable dose and pre-brewing cycle time. 1.2 Operating cycle When one of the coffee buttons is pressed for one of 3. BUTTON PANELS the 4 dispensers, the following occurs: 3.1 coffee Button Panel - The dispensing solenoid valves are energized and the pump motor starts for a time that can be programmed between 0 and 10 sec - The dispensing solenoid valves are de-energized and the pump motor stops for a time that can be programmed between 0 and 10 sec - The dispensing solenoid valves are energized and the pump motor starts until the programmed impulses are reached, which start decreasing during the first phase.
  • Page 5 3.3 Programming Panel The machine carries out n. 2 cycles as follows: - Starts dispensing from the groups for 0 sec. This panel features 4 buttons with the following - Pauses for 0 sec. functions: Keeping ‘’esc’’ pressed for 2 seconds, during the cycle the current washing phase will stop and the next phase will take place. It is advisable to always complete the rinsing cycle to remove any detergent residues. N.B. In the washing and rinsing phases the groups are operated alternatively. In any case the washing of the coffee groups can be enabled whenever necessary according to the Button with “+” sign previously described procedure.
  • Page 6 4. INSTALLATION mENU When the coffee machine is switched on for the first time, the following installation menu is displayed in se- quence: - Language selection - Pressure unit - Temperature unit - Softner unit - Date mode - Clock mode - Clock setting - Pressure setting - Cleaning reminder If no changes are required, press “esc”, in order to continue with installation. 5. PrOGrAmmING Programming is carried out on two levels, namely: “Bartender” programming...
  • Page 7 5.2.1.1 Pressure adjustments 5.2 The “Technician’s” Menu Enables adjustment of the boiler pressure from 0.60 When the “+” and “ – “buttons are pressed for appro- to 1.40 bar, in 0.05 bar steps. The default pressure ximately 4 seconds, the “technician’s” programming setting here is 1.00 bar. menu is activated. This menu contains the following submenus: 5.2.1.2 coffee dose programming To set the coffee groups and water doses: - Setup v cOffEE GrOUP - Counters - Graphics - Number of impulses by the flow meter.
  • Page 8 5.2.1.10 Level sensor Once dispensing has ended, the following comes up on display: Sets the type of boiler water level sensor: - OK (if the dispensing time is comprised in ± 15% - Level indicator rod of the time stored) - Deviation time in seconds (if the dispensing - Capacitive board (default) time is out of the ± 15% tolerance) 5.2.1.11 Error codes log In both of these functions, the display shows pro- gressive cup fill-up based on the impulses being Display of the machine error logs (ref. par. 9). Displays...
  • Page 9 5.2.5.2 Wash cycle counter It is possible to interrupt display of logos in the event Displays the number of coffee wash cycles that have been performed. Coffee dispensing Hot water/4-TEA dispensing 5.2.6 Data interfaces iSteam dispensing 5.2.4 iSteam DATA CONNECTION IDS INTERFACES ISTEAM ISTEAM MODULE Setting of the Rancilio IDS (Interface Data System) for data interfacing. It is possible to set either the DEBIT operating func- FOAMED MILK tion (data discharge only) or the CREDIT operating function (with dispensing enabled via the cashbox system). In the event that this function is enabled without the STEAMED MILK interface, the machine will go into block mode. 5.2.4.1 iSteam presence Provides for setting of iSteam presence in the ma- chine. 5.2.4.2 milk frothing Setting of the milk’s final temperature and emulsion...
  • Page 10 5.2.7 Diagnostics 5.2.7.5 Level inputs Selecting the type of boiler water level sensor in- stalled, it is possible to view the status of the boiler DIAGNOSTIC SOLENOID VALVES water level: - OFF (level not reached) - ON (level OK) HEATINGS ELEMENTS 5.2.7.6 Analogue inputs Provide for instant viewing of the real-time bit values detected by the probes. BUTTONS AND LEDS 5.2.7.7 LcD contrast Shows the display contrast level. FLOWMETERS 5.2.7.8 LcD back-lighting Shows the display back-lighting level. WATER LEVEL TEST 5.2.7.9 counters Display of the following values: - Number of pump-cycle activations. ANALOGIC INLETS TEST - Total pump-operation time (in hours).
  • Page 11 6.2. Operating mode If one of the two time/doses control functions are activated, the coffee symbol space will instead Once the temperature/pressure is reached, the date, display: the current time and the pressure data will stay on display (for 20 sec.) and flash alternatively to the customisation logos. During dispensing, the following is displayed: otherwise: “Brewing time ” For energy saving purposes, the display will reduce its luminosity after one hour of continuous inactivity without dispensing anything. After two hours of con- tinuous inactivity without dispensing anything, it will switch itself off altogether. 7. OPErATING SAfETY DEVIcES When the coffee maker is switched ON, it checks whether there is enough water in the boiler.
  • Page 12: List Of Malfunctions

    9. LIST Of mALfUNcTIONS W2 Interr. EV cold 4-TEA W24 EV hot 4-TEA shorted The system electronics are capable of diagnosing W25 Interr. EV hot 4-TEA the following failures by displaying the relative error W26 EV steam iSteam shorted codes on screen: W27 Interr. EV steam iSteam Because they are serious, these errors will stop and W0 EV air iSteam shorted block machine operations. W1 Interr. EV air iSteam G00 Check CPU W32 Check the message file W Check USB G01 Water missing G02 Boiler Pressure low G0 Boiler probe shorted G04 Interrupted boiler probe G05 Connection IDS G06...
  • Page 13 ITALY Rancilio North America Inc. Rancilio Macchine per caffè S.p.A. 8102 S.Lemont Rd. #1200 Viale della Repubblica 40 Woodridge, IL 60517 USA 20010 Villastanza di Parabiago Tel +1 630 427 1703 Milano Italy Fax +1 630 427 1713 Tel +39 0331 408200 www.rancilio.com...
  • Page 14 www.rancilio.com...

This manual is also suitable for:

Classe 10s