4.2.10 Controller Panel Assy

1)
Open the top cover.
(2)
Open the feeder unit.
(3)
Detach the right side cover. (See Subsection 4.2.3.)
(4)
Remove the plate shield assembly. [See Subsection 4.2.7 (2).]
(5)
After unplugging the connector of the control panel assembly, free the hook.
Remove four screws (silver) 1, and detach control panel Assy 2. (Tool No. 1)
(6)
43085101TH Rev.1
Top cover
Figure 4-2-10 Control Panel Assy
Oki Data CONFIDENTIAL
1
2
1
Feeder unit