Oki C5500 Maintenance Manual page 163

Table of Contents

Advertisement

Display on Operator Panel
LOAD %MEDIA_SIZE%
%ERRCODE%:%TRAY% EMPTY
LOAD %MEDIA_SIZE% AND PRESS
ONLINE SWITCH
%ERRCODE%:MP TRAY EMPTY
INSTALL PAPER CASSETTE
%ERRCODE%:TRAY1 OPEN
INSTALL PAPER CASSETTE
%ERRCODE%:%TRAY% MISSING
ADD MORE MEMORY
%ERRCODE%:MEMORY OVERFLOW
PROTEC PAPER
%ERRCODE%:ERROR
43085101TH Rev.1
Table 7-1-1 Operator Alarm (3/9)
Ready
Attention
LED
LED
Off
Blink
Printing request is issued to an empty tray.
Load paper.
(It takes a while until the status disappears after you
have closed the tray and the lever lifted.)
Error 491 : Tray1
Error 492 : Tray2
The paper size displaying form of the custom mode is
the same as above.
In this state, Leisus I/F : corresponding bits of both
LFTERR and LFTERR2 should be '0' (except MPTray).
Off
Blink
Printing request is issued to an empty MPTray.
If it goes through a definite period of time (PU firmware
holds time(3 sec)) after a user places paper, a printer will
lift up the multipurpose tray, and will perform re-feeding.
If a user pushes the ONLINE button before timeout, the
printer perform also re-feeding,.
Error 490 : MPTray
In this state, Leisus I/F : corresponding bits of both
LFTERR and LFTERR2 should be '0'.
Programmer's note: When the ONLINE button was
pressed, the controller (CU) should send MPTPECLR
command to the engine (PU). The engine would clear
this state after receiving that command.
This error is occurred, when the MPTray is in the home
position and the sensor "PE SNS2" cannot detect
papers.
Off
Blink
Indicates removal of the paper cassette of Tray 1 that is
a paper path in attempting to print from Tray 2.
Off
Blink
Indicates that paper feed is unavailable in attempting to
print from Tray 1 due to removal of the paper cassette of
Tray 1. (Occurs only when Tray 2 has been installed.)
Off
Blink
Memory capacity overflows due to the following reason.
Press ON-LINE switch so that it continues. Install
expansion RAM or decrease the data amount.
- Too much print data in a page.
- Too much Macro data.
- Too much DLL data.
- After frame buffer compression, over flow occurred.
Off
Blink
This error occurs if a received job does not meet the
security level designated by a printer administrator. A
printing operator is not using the printer driver that is
specified by a security manager of the printer.
Displays a warning on the operation panel as waiting for
key press. Does not print the job that is being processed.
(The same operation as job reset) (C6100)
Oki Data CONFIDENTIAL
Description
Code
nnn
Error
491
492
Error
490
Error
440
Error
430
Error
420
Error
421