(1)
Open the top cover.
(2)
Detach the right side cover. (See Subsection 4.2.2.)
Remove eight screws (silver) 1, and detach plate shield Assy(GDI)2 by releasing claws A.
(3)
(Tool No. 1)
Remove screw (silver) 3, and disconnect head cable 4. (Tool No. 1)
(4)
Remove seven screws (silver) 5, disconnect all the cables, and disassemble control PCB
(5)
(SP1 PCB) 6. (Tool No. 1)
43085101TH Rev.1
Figure 4-2-6-2 Controller PCB (C5800)