Fan Thermistor - Asko TL751 XXLW Service Manual

Hide thumbs Also See for TL751 XXLW:
Table of Contents

Advertisement

1. Function
• The fan thermistor senses the temperature of exhaust air.
• The higher the temperature is, the smaller the resistance is.
2. Specification
• A bimetal thermostat with the terminals normally closed
at 90°C : R = 4.43 kΩ
at 40°C : R = 26.07 kΩ
• Type name : CWT-DWE-1C18-A
3. Checking method of malfunction
• If the resistance between terminals is within the adequate range, the fan is in normal operation.
• You can test the resistance of the thermistor as follows.
- Put the metal rod into cold water 50~68°F(10~20°C): 40 within 30 seconds
- Put the metal rod into boiling water 205~212°F(95~100°C): 4 within 30 seconds
• If 'H2' error is displayed when you press the power and start button, the thermistor is not closed so
replace it.
4. Procedure of replacement
1 Remove Top Plate
2 Remove Front Panel Assembly
3 Remove Cabinet Front Assembly
4 Remove Upper Frame
5 Remove Drum Assembly
6 Check the position of the part.
7 Remove wires and 1 screw to detach the part.
8 Assemble the parts in reverse order.
Thermistor Fan

Fan Thermistor

43
Part Code : 361AAAAC20