1. Function
• This is an assembly that heats air in the drum.
• Two 2500-W upper/lower heaters are connected in a parallel circuit,
producing 5,000W
• According to the program set, either one or two heaters operate.
2. Specification
• Two heaters with the same specification are connected in a parallel circuit.
• Single heater: Ni/Cr wire 0.8mm, 6 coil turns,
2500W rated output based on 240V
• Electric rating : 240V 5000W (2500W x 2)
• Type name : TGE-24050H
3. Checking method of malfunction
• Check if the resistance of both ends is 17.3~25.9.
(For your safety and accurate measurement, check the resistance after running 'Dry Air' program for
more than 5 minutes).
• If the resistance is beyond the range, replace the heater.
• Do not use a heater of which the coils have too narrow width or drooped excessively.
4. Procedure of replacement
1 Remove the back cover.
2 Remove the wires of duct inlet ass'y and screws to disassemble the part.
Loosen the 4 screws as indicated
with a circle.
5 Assemble the parts in reverse order.

Heater Assembly

Heater A (upper)
Heater B (lower)
3 Remove all screws of duct inlet ass'y and detach the
duct inlet front.
4 Remove the heater and install a new one.
40
Part Code : 3612802500
Heater Ass'y