Asko TL751 XXLW Service Manual page 26

Hide thumbs Also See for TL751 XXLW:
Table of Contents

Advertisement

2-8. TEST Mode
1) PCB TEST MODE
A. How to enter the mode: Turn the power on while pressing Dry Sensor and Temp. buttons.
B. Operation order : check load by pressing Dry Time button continually.
No.
Operation Load
1
F PCB LED ALL On
2
Humidity sensor check
3
Temp sensor check
4
Door S/W check
5
Motor check
6
Heater-Outer check
7
Heater-Inner check
8
Power off
Total time
Fixed resistance of the temp sensor : 1.7 KΩ
2) TEST MODE
A. How to enter the mode: Turn the power on while pressing Dry Sensor and Dry Time buttons.
B. Operation order: check load by pressing Dry Time button continually.
No.
Operation Load
1
Motor On
2
Heater 1 on
3
Heater 2 on
4
Heater 1, Heater 2 off
5
Humidity sensor check
6
Temp sensor check
Open the door at 6th pressing
Press the start button
after closing the door.
Power off
Total time
Time (Sec)
DISPLAY
6.0
ALL LED
2.0
1 : xx
2.0
2 : xx
2.0
dc --> do
2.0
2.0
H1
2.0
H2
0.3
F
18 seconds
Time (Sec)
DISPLAY
0.5
1 : nr
0.5
2 : H1
0.5
3 : H2
0.5
4 : nr
1.0
5 : number
0.5
6 : number
0.5
6:00
0.5
6: number (Motor on)
0.3
Power section
About 5 seconds
25
Miscellaneous
Miscellaneous
Current : 13A
Current : 23.5A
Check based on the
variations of numbers
Surrounding temp indicated
Motor off
Door S/W check