1. Function
• This is a bimetal-type switch which controls the heater operation.
• If the heater is too hot, this thermostat stops the heater and after the heater
is cooled down, it restarts the heater.
2. Specification
• A bimetal thermostat with the terminals normally connected
• Electric rating : 25A at 125V
• Opening temperature : 257°F (125°C) ±5, Closing temperature : 201°F (94°C) ±5
• Type name : 60T
3. Checking method of malfunction
• After 3 minutes of the air dry program, the terminals of this part are closed.
• Press the power and start buttons while you push the door switch after opening the door.
• Check if the heater operates after the drum starts rotating.
(To do this, check if the heater turns red or feel warm air in the drum with your hands).
• If the heater operates, run the air dry program for more than 3 minutes after closing the door.
• Switch off the power and measure the resistance between the terminals. If the value is greater than 1,
replace the switch.
4. Procedure of replacement
1 Remove the back cover.
2 Check the position of the part
3 Remove the wires and screws to disassemble the part.
4 Assemble the parts in reverse order.