4-wire connection : Direct wire
Important : Grounding through the neutral conductor is prohibited for (1)
new branch-circuit installations, (2) mobile homes, (3)
recreational vehicles, and (4) areas where local codes
prohibit grounding through the neutral conductor. Prepare
minimum 5 ft (1.52 m) of length in order for dryer to be
replaced. First, peel 5 inches (12.7 cm) of covering material
from end. Strip 5 inches of ground wire insulation. After
cutting 11/2 inch (3.8 cm) from 3 other wires peel insulation
back 1 inch (2.5 cm). Make ends of 3 wires a hook shape.
Then, put the hooked shape end of the wire under the screw of the terminal block (hooked end facing to
the right) and pinch the hook together and screw tightly.
1. Connect neutral wire (white) of power cord to center terminal block screw.
2. Connect red and black wires to the left and right terminal block screws.
3. Connect ground wire (green) of power cord to external ground screw and move neutral ground wire of
appliance and connect it to center screw.
4. Make sure that the strain relief screw is tightened.
Be sure that all terminal block nuts are on tight and power cord is in right position.