2-3. Operation of Load and Sensor
1) Operation of Heater - Electric Type
On/Off goes on according to temperatures set or measured by the sensor. Regardless of the control by
the microcomputer, however, the heater may go off if a temperature reaches Thermostat Off
Temperature as per outlet conditions.
As regards temperature setting, refer to 2-4 (button operation and temp control).
If you stop the unit temporarily, the machine stops operating until it resumes the function.
If Sensor Course is selected and Temp Control is set to Low or Ultra Low, only the outer heater
operates. Two heaters function if other temperatures are selected.
If Manual Course is selected and Temp Control is set to Low or Ultra Low, only the outer heater
operates. Two heaters function if other temperatures are selected.
If Time Dry Course is selected and Temp Control is set to Ultra Low, only the outer heater operates.
Two heaters function if the temperature is set to Low.
The heater goes off if Cooling or Wrinkle Care is selected.
The heater goes off if Air-Dry of Manual Course is selected, for Temp Control is not available.
2) Operation of the Motor
The motor continues its function once operation starts.
The motor stops if you stop the unit temporarily.
The motor continues to operate during Cooling.
If Cooling or Wrinkle Care is selected, the motor turns on for 10 seconds and off for 5 minutes and 50
seconds.
3) Door Control
The heater and motor operate only the door is closed.
If the door is opened during the operation, the heater and motor turn off. If you press Start Button while
the door is opened, LED goes on for a second.
The unit operates only after the door is closed.