Trouble Shooting Guide - Napoleon GVF40N Installation And Operation Instructions Manual

Unvented millivolt system natural and propane gas fireplace
Table of Contents

Advertisement

22
SYMPTOM
Main burner goes
Pilot flame is not large
out; pilot stays on.
enough or not engulfing the
thermopile
Thermopile shorting
Remote wall switch wire is
too long; too much resist-
ance in the system.
Faulty thermostat or switch.
Main burner goes
Insufficient air supply
out; pilot goes out.
Out of propane gas.
Pilot flame is not large
enough. (Supply pressure
too low.)
Pilot goes out when
System is not correctly
the gas knob is re-
purged.
leased.
Out of propane gas.
The gas valve has
Pilot flame is not large
an interlock device
enough. (Supply pressure
which will not allow
too low.)
the pilot burner to
be lit until the ther-
Thermocouple shorting /
mocouple
has
faulty.
cooled. Allow ap-
proximately
60
seconds for the
thermocouple to
Faulty valve.
cool.
Themostat or switch is de-
Pilot burning; no
fective.
gas
to
main
burner; gas knob
Wall switch wiring is defec-
is on 'HI'; wall
tive.
switch / thermostat
is on.
Main burner orifice is plugged.
Faulty valve.
Pilot will not light.
Out of propane gas
No spark at pilot burner
THERMOPILE
THERMOCOUPLE
PILOT
BURNER
No gas at the pilot burner
ELECTRODE
W415-0319 / D / 08.03.05

TROUBLE SHOOTING GUIDE

PROBLEM
- service or replace Oxygen Depletion Sensor System
- correct piping and/or regulator to provide correct pressure
- clean thermopile connection to the valve. Reconnect.
- replace Oxygen Depletion Sensor System / valve.
- shorten wire to correct length or wire gauge.
- replace.
- open window or door. (Use one of the methods described in ANSI
Z223.1 Section 5.3 or the applicable local code.)
- fill the tank.
- service or replace Oxygen Depletion Sensor System
- correct piping and / or regulator to provide correct pressure.
- purge the gas line. If a glass door has been installed, ensure that
the door is open or removed prior to purging.
- fill the tank.
- service or replace Oxygen Depletion Sensor System
- loosen and tighten thermocouple.
- clean thermocouple and valve connection.
- replace Oxygen Depletion Sensor System
- test and replace valve.
- replace.
- remove stoppage in orifice.
- replace.
- fill the tank.
- check if pilot can be lit by a match
- check that the wire is connected to the push button ignitor.
- check if the push button ignitor needs tightening.
- replace the wire if the wire insulation is broken or frayed.
- replace the electrode if the ceramic insulator is cracked or broken.
- replace the push button ignitor.
- check that the manual valve is turned on.
- check the pilot orifice for blockage.
- replace the valve / Oxygen Depletion Sensor System.
- call the gas distributor.
TEST SOLUTION
- connect a jumper wire across the wall switch terminals; if main
burner lights, replace switch / thermostat.
- disconnect wires from valve. Connect a jumper wire across termi-
nals 1 & 3; if the main burner lights, check the wires for defects and
/ or replace wires.