These log sets can be installed in vented or unvented applications. See installation details for the
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
CERTIFIED UNDER: ANSI Z21.11.2a-2008 GAS FIRED ROOM HEATER : VOLUME II, UNVENTED ROOM HEATERS
ANSI Z21.60b-2004 / CSA 2.26b-2004 DECORATIVE GAS APPLIANCES FOR INSTALLATION IN SOLID-FUEL BURNING APPLIANCES
GVFL18N, GVFL24N,
GVFL30N
NATURAL GAS
GVFL18P, GVFL24P,
GVFL30P
PROPANE
CERTIFIED FOR THE UNITED STATES USING ANSI METHODS.
SAFETY INFORMATION
WARNING
!
If the information in these instructions are
not followed exactly, a fi re or explosion
may result causing property damage,
personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
- This is an unvented gas-fi red heater that
uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and
ventilation air must be provided.
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com
10.00$
particular application that applies.
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
INSTALLATION AND
GVFL18
GVFL24
GVFL30
W415-0809 / C / 08.29.18
1.23
1

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon Fiberglow GVFL24N

  • Page 1 Provisions for adequate combustion and ventilation air must be provided. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com W415-0809 / C / 08.29.18...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INSTALLATION OVERVIEW INTRODUCTION DIMENSIONS 2.1.1 GVFL18 2.1.2 GVFL24 2.1.3 GVFL30 GENERAL INSTRUCTIONS GENERAL INFORMATION MINIMUM APPLIANCE SIZE RATING PLATE INFORMATION INSTALLATION INSTALLING IN AN UNVENTED APPLICATION 3.1.1 COMBUSTION AND VENTILATION AIR PROVISIONS 3.1.2 DETERMINING CONFINED OR UNCONFINED SPACE INSTALLING IN A VENTED APPLICATION 3.2.1 DAMPER STOP INSTALLATION...
  • Page 3: Introduction

    2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • ANY CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. • Under no circumstances should this appliance be modifi ed. •...
  • Page 4: Dimensions

    DIMENSIONS 2.1.1 GVFL18 13.250 20.500 24.000 2.1.2 GVFL24 24.000 13.250 26.250 2.1.3 GVFL30 24.000 22.750 1.500 13.250 30.250 W415-0809 / C / 08.29.18...
  • Page 5: General Instructions

    Sellers of unvented propane or natural gas-fi red space/room appliances shall provide to each purchaser a copy of 527 CMR 30.00 upon the sale of the appliance from http://www.napoleonfi replaces.com/Webshare/installation_manuals/mass_requirements.pdf • A carbon monoxide detector is required in all rooms containing gas fi red appliances.
  • Page 6: General Information

    (NFI) as ® Napoleon’s two vent free fi rebox enclosures the ZCVF NFI Gas Specialists. 36/42 can be used to house all 3 of Napoleon’s vent free www.nficertified.org log sets, the GVFL 18, 24 and 30. MINIMUM APPLIANCE SIZE Each gas log set must be installed into a appliance cavity...
  • Page 7: Rating Plate Information

    THIS APPLIANCE IS NOT FIELD CONVERTIBLE FOR USE WITH OTHER GASES. XXXXXX WOLF STEEL LTD. WOLF STEEL L 24 NAPOLEON ROAD. BARRIE, ONTARIO L4M 4Y8 CANADA 24 NAPOLEON RO W385-0317 / K THE RATING PLATE IS CHAINED TO THE PIEZO IGNITOR BRACKET AND SHOULD BE TUCKED UNDER THE ENTIRE ASSEMBLY This illustration is for reference only.
  • Page 8: Installation

    3.0 INSTALLATION INSTALLING IN AN UNVENTED APPLICATION WARNING BARRIERS SUCH AS THE BOTTOM OF A GLASS DOOR FRAME PLACED IN FRONT OF A GAS LOG SET CAN CHANGE THE AIR FLOW CHARACTERISTICS OF THE APPLIANCE WHICH IN TURN CAN CAUSE THE APPLIANCE TO CARBON OR OVERHEAT AND MALFUNCTION. During manufacturing, fabricating and shipping various components of this appliance are treated with certain oils, fi...
  • Page 9 B) Weather stripping has been added on openable windows and doors, and C) Caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and fl oors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.
  • Page 10: Installing In A Vented Application

    INSTALLING IN A VENTED APPLICATION The appliance and gas logs function as a system. If the appliance is not drafting properly and spilling into the room (check with a match or a smoke stick), reposition the damper clamp until a positive draft is obtained by opening the damper.
  • Page 11: Gas Piping

    GAS PIPING WARNING DO NOT CONNECT EITHER THE WALL SWITCH, THERMOSTAT OR GAS VALVE TO ELECTRICITY (110 VOLTS). This appliance and it’s appliance main valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ PSI (3.5kPa) Manual This appliance must be isolated from the gas supply piping Regulator...
  • Page 12: Log Placement

    Do not place glowing embers, charcoal embers, vermiculite or charcoal lumps on this burner. Phazer logs, exclusive to Napoleon Appliances, provide a unique and realistic glowing effect that is different in every installation. These logs are fuel specifi c. Do not interchange. Refer to the replacement parts list.
  • Page 13: Logo Placement

    LOGO PLACEMENT Remove the backing of the logo supplied. Centre the logo on the front of the appliance, ½” in from the left side, as shown. ½" ½" MEDIA GVFL 18 Place lava or ember rock around the base of the appliance, making sure not to block any burner ports or valve access.
  • Page 14: Operating Instructions

    5.0 OPERATING INSTRUCTIONS If the appliance is equipped with decorative glass doors, they must be fully opened when operating this gas log set. LIGHTING INSTRUCTIONS Locate the pilot burner at the rear of the log set on the right side. Turn the gas control knob to the pilot setting (on the left side of the appliance closest to the back).
  • Page 15: Operation

    6.0 OPERATION WARNING When lit for the first time, the appliance will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of the logs and the “burn-in” of internal paints and lubricants used in the manufacturing process and will not occur again. After extended periods of non-operation such as following a vacation or a warm weather season, the appliance may emit a slight odour for a few hours.
  • Page 16: Adjustments

    7.0 ADJUSTMENTS AIR SHUTTER WARNING CARBON CAN BE DISTRIBUTED IN SURROUNDING LIVING AREAS IF THE AIR SHUTTER IS IMPROPERLY ADJUSTED. FAILURE TO KEEP THE PRIMARY AIR OPENING(S) OF THE BURNER (S) CLEAN MAY RESULT IN SOOTING AND PROPERTY DAMAGE. The air shutter settings are factory set for most installations. However, LOG SET AIR SHUTTER adjustment may be required depending on fuel type, vent performance and...
  • Page 17: Replacements

    #50 ORIFICE - LP W660-0023 ON / OFF SWITCH W725-0030 VALVE - NG W725-0031 VALVE - LP W385-0334 NAPOLEON LOGO W662-0003 NATURAL GAS - OXYGEN DEPLETION SENSOR W662-0004 PROPANE GAS - OXYGEN DEPLETION SENSOR W135-0394 FIBRE BURNER COVER W010-2120 WELDED BURNER ASSEMBLY...
  • Page 18 W415-0809 / C / 08.29.18...
  • Page 19: Trouble Shooting

    10.0 TROUBLE SHOOTING WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS.
  • Page 20 SYMPTOM PROBLEM TEST SOLUTION Pilot burning; Thermostat or switch is Connect a jumper wire across the wall switch no gas to main defective. terminals; if main burner lights, replace switch / burner; gas thermostat. knob is on ‘HI’; Wall switch wiring is Disconnect wires from valve.
  • Page 21 SYMPTOM PROBLEM TEST SOLUTION Flames are Unit is over-fi red or under- Check pressure readings: consistently too fi red. Inlet pressure can be checked by turning screw (A) large or too small. counter-clockwise 2 or 3 turns and then placing Carboning occurs.
  • Page 22: Warranty

    All parts replaced under the President’s Limited Lifetime Warranty Policy are subject to a single claim. During the fi rst 10 years NAPOLEON® will replace or repair the defective parts covered by the lifetime warranty at our discretion free of charge. From 10 years to life, NAPOLEON® will provide replacement parts at 50% of the current retail price.
  • Page 23: Service History

    12.0 SERVICE HISTORY 43.1 W415-0809 / C / 08.29.18...