TROUBLE SHOOTING GUIDE

B
EFORE ATTEMPTING TO TROUBLESHOOT
SYMPTOM
Main burner fl ame
Blockage in vent.
is a blue, lazy,
transparent fl ame.
Incorrect installation.
Flames are consis-
Unit is over-fi red or under-
tently too large or
fi red.
too small. Carbon-
ing occurs.
B
Carbon is being de-
Air shutter has become
posited on glass,
blocked
logs or combustion
Flame is impinging on the
chamber surfaces.
rocks or combustion cham-
ber.
White / grey film
Sulphur from fuel is being
forms.
deposited on glass, logs or
combustion chamber sur-
faces.
E x h a u s t f u m e s
Fireplace is spilling.
smelled in room,
headaches.
Pilot goes out when
S y s t e m i s n o t c o r r e c t l y
the gas knob is re-
purged.
leased.
Out of propane gas.
The gas valve has
Pilot flame is not large
an interlock device
enough
which will not al-
low the pilot burn-
Pilot fl ame is not engulfi ng the
er to be lit until
thermocouple.
the thermocouple
Thermocouple shorting /
has cooled. Allow
faulty.
approximately 60
seconds for the
thermocouple to
cool.
Faulty valve.
W415-0666 / 01.28.08
,
PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR OPEN
PROBLEM
- remove blockage. In really cold conditions, ice buildup may occur on
the terminal and should be removed as required.
- ensure correct location of storm collars.
- check pressure readings:
Inlet pressure can be checked by turning screw (A) counter-clockwise
2 or 3 turns and then placing pressure gauge tubing over the test point.
Gauge should read 7" (minimum 4.5") water column for natural gas or
13" (11" minimum) water column for propane. Check that main burner
A
is operating on "HI".
Outlet pressure can be checked the same as above using screw (B).
Gauge should read 3.5" water column for natural gas or 10" water col-
umn for propane. Check that main burner is operating on "HI".
AFTER TAKING PRESSURE READINGS, BE SURE TO TURN
SCREWS CLOCKWISE FIRMLY TO RESEAL. DO NOT OVER-
TORQUE.
Leak test with a soap and water solution.
- ensure air shutter opening is free of lint or other obstructions.
- check that the bowl and rockset are correctly positioned.
- open air shutter to increase the primary air.
- check the input rate: check the manifold pressure and orifi ce size as
specifi ed by the rating plate values.
- check that the door gasketing is not broken or missing and that the
seal is tight.
- check that both 4" and 7" vent liners are free of holes and well sealed
at all joints.
- check that minimum rise per foot has been adhered to for any hori-
zontal venting.
- clean the glass with a gas fi replace glass cleaner. DO NOT CLEAN
GLASS WHEN HOT.
If deposits are not cleaned off regularly, the glass may become per-
manently marked.
- check door seal and relief fl ap seal.
- check for chimney blockage
- check that the paint curing process is complete
- purge the gas line with the glass door open.
- fi ll the tank.
- turn up the pilot fl ame.
- gently twist the pilot head to improve the fl ame pattern around the
thermocouple.
- loosen and tighten thermocouple.
- clean thermocouple and valve connection.
- replace thermocouple.
- replace valve.
- replace.
TEST SOLUTION
.