GVF103-KT - PATENTED CATALYTIC
DOOR INSTALLATION
Notes:
Ornamental insets can not be used in conjunction
with the catalytic door
When using a catalytic door, glassed doors must
be used on all other side or end openings.
This unique patented catalytic system was designed to
provide unparalleled safety and peace of mind. The top of
the door contains four catalytic tiles which are designed to
filter out combustion gases and limit the carbon monox-
ide output. It is likely that with the fireplace in operation, the
catalytic tiles will actually scrub the carbon monoxide nor-
mally found in the room and reduce it to a lower level. The
tiles must not be altered or removed. They are not field
serviceable and must be tested annually. The hood sup-
plied with the unit must be disgarded and replaced with
the hood designed for use with the catalytic door.
The heater with an optional catalytic door in place must
not be operated when using any products such as paint,
paint thinner, adhesives, etc. These products will perma-
nently affect the catalytic tiles' ability to scrub the air.
FIGURES 35
1
1. The mesh must be removed if the catalytic door is used.
Remove the centre bracket and bend the curtain rod slightly
to disengage the rod from either side.
LATCH SCREW
LOCATION
CURTAIN SUPPORT PLATE
2. Remove the curtain support plate. Remove the two latch
securing screws, already installed, position latch as shown
in
4
and re-secure with the screws. A ¼" socket ratchet is
recommended for this.
Repeat at the bottom. For location, see
W415-0319 / D / 08.03.05
OPTIONS
CURTAIN ROD
BRACKET
2
5
.
3. Screw the door hinge
onto the heater by first start-
ing each of the five ma-
chine screws and then
tightening all screws.
TOP DOOR LATCH
4
BOTTOM DOOR LATCH
5
4. & 5. Secure the door using the two latches.
Install the appropriate hood by hooking it over the top lip of
the door assembly.
The heater must not be used when the hood is removed.
DOOR OPENING AND CLOSING
FLANGE
CLIP
HOOD
UPPER LOUVRE
DOOR LATCH
36
Care must be taken when closing and opening the cata-
lytic door to avoid damaging the catalytic tiles.
DOOR
HINGE
3
The upper louvres must
be removed to allow the
catalytic door to be
opened or closed. To ac-
cess the lower door latch,
open the valve control
door. Release the top and
bottom door latches, lo-
cated at the right side of
the door.