Maintenance Manual
Quarterly Maintenance Procedures
1 Run
2 Bypass
3 Recovery
1
Turn the key switch to the ground control and
pull out the red Emergency Stop button to the
on position. Start the engine.
Z-80, Z-135 and ZX-135 models:
2
Fully raise the secondary boom then extend it
approximately 4 ft / 1.2 m.
All models:
3
Raise the primary boom approximately 15°
then extend it approximately 4 ft / 1.2 m.
4
Turn the key switch to the off position to turn
off the engine. Turn the key switch back to
ground controls.
Note: If this procedure is performed with the main
key switch in the off position an active latched
safety fault will be set and will have to be cleared.
58
5
Remove the key from the main key switch and
insert the key into the bypass/recovery key
switch.
Note: The bypass/recovery key switch is located
on the front panel in the lower right corner on Z-80
before serial number Z8013-3911 and Z-135
before serial number Z13512-1712.
6
Turn and hold the bypass/recovery key switch
to the recovery position. The switch must be
held in the recovery position.
Result: The emergency power unit will turn on
and the boom will begin the following recovery
sequence.
SX-150, SX-180, S-100/105/120/125,
S-100/120HD:
• The primary boom will retract
• The primary boom will lower
Z-135 and ZX-135:
• The primary boom will retract
• The secondary boom will retract
• The primary boom will lower
Note: It is not necessary to fully lower the primary
boom.
Z-80/60:
• The primary boom will retract
• The primary boom will lower
• The secondary boom will retract
7
Turn the bypass/recovery key switch to the
run position.
8
Remove the key from the bypass/recovery
key switch and insert the key into the main
key switch.
9
Start the engine and return the boom to the
stowed position.
S Booms • Z Booms
April 2016
Part No. 1268489