11.
Engaging lever
05.06
Requirement
With the needle bar at TDC and with control lever 3 at starting position, there must be a
distance of approx. 0.3 mm between bolt 4 and the outer diameter of control cam 5.
5
3
5
Fig. 11 - 22
Bring the needle bar to TDC by turning the handwheel.
Turn screw 1 (nut 2) in accordance with the requirement.
Carry out a check by tapping control lever 3.
3
4
Adjustment
1
2
11 - 25