Adjustment
13
Engaging lever
.05.06
● Move the needle bar to t.d.c. by turning the handwheel.
● Turn the screw 1 ( nut 2 ) according to the rule.
● Carry out a check by tapping on the tripping lever 3.
22
Rule
When the needle bar is in t.d.c. and the tripping lever 3 is in the basic position, there
should be a clearance of approx. 0.3 mm between the bolt 4 and the outside diameter of
the control cam 5.
3
4
5
Fig. 13 - 17
5
3
2
1