11.
Pre-adjusting the needle height
04.04
Requirement
With the needle bar at BDC, the distance between the needle bar and the needle plate
must be 15 mm.
Fig. 11 - 04
Move needle bar 1 (screw 2) in accordance with the requirement without moving it
laterally.
2
1
Adjustment
15 mm
11 - 5