After the expiration of the aforementioned 5 seconds within which you should
CYCLE
09:02:37
C-D
PM
have at least made the choice of a particular cycle mode as well as the input of
00
NiCd Auto Mode
a delayed start, it starts an automatic battery test.
Charge Mode
0
AUTO
If no battery is connected, or an improper battery is detected, after completion
Discharge Mode
of the battery test it will be shown an appropriate error message, see „Alert
AUTO
messages" on page 48.
Battery check!!
Start Verz. Zeit
Checking Battery ...
0 0:0 0 : 0 0
CH1
CH2
NiCd and NiMH batteries cycling process starts as described below by way of
CYCLUS
09:02:47
C-D
PM
example for a lithium battery after about 5 seconds.
13 LiPo 03s
2200
For lithium batteries and PB after few seconds the battery test, it is carried out
Charge Mode
5
CC/CV
a review of the number of cells connected batteries.
Discharge Mode
NORMAL
Connected Cells
Start Verz. Zeit
[ 3 ] cells are now
example.
connected at the
00 :00 :0 0
balancing port.
CH1
CH2
CYCLE
09:02:47
C-D
PM
13 LiPo 03s
2200
Charge Mode
5
the example shown to the left.
CC/CV
If the displayed number of cells matches the actual number of cells of the con-
Discharge Mode
NORMAL
nected battery, wait until after about 5 seconds - as described below - charge
will start automatically.
Select Cells
Start Verz. Zeit
Select[ 3 ] cells to be
charged or discharged
00 :00 :0 0
CH1
CH2
CYCLE
09:02:47
C-D
PM
13 LiPo 03s
2200
Cherge Mode
5
cells with one of these buttons accordingly. As an indication of the manual
CC/CV
intervention changes the color of the header information when prompted be-
Discharge Mode
NORMAL
tween red and blue.
Zellenzahl auswählen
** Check Cells **
Start Verz. Zeit
Select [ 4 ] cells to be
charged or discharged
00 :00 :0 0
plode and / or burn!
Press the ENTER button on the bottom right to start the cycle process.
CH1
CH2
30
Is the battery to cycle connected not only with the charger, but also
with a balancer to the charger, the cell count is determined by the
balancer and the outcome of the review appears as shown on the left
The detected cell count is based on the current battery voltage and
the outcome of the review - if the lithium or PB battery to cycle is con-
nected only with the charge cable to the charger, which appears as
If the displayed number of cells, however, is NOT matching the actual
number of cells of the battery connected, then stop the automatic
timing by pressing the INC or DEC key and then adjust the number of
ATTENTION!
!
As a result of incorrectly set number of cells or even a value too
far from cell voltages due to the balancer port, battery can ex-