GRAUPNER POLARON EX-1400 Operating Instructions Manual page 20

2 channel charger
Hide thumbs Also See for POLARON EX-1400:
Table of Contents

Advertisement

Lead batteries
Parameter
Voltage
Current
Maximal Tempera-
ture
Maximal capacity
Safety timer
Once the settings are matching with your wishes, go to ...
Start the charge process
... Press the ENTER button on the bottom right of the display on the second
CH A R GE
05:39:46
PM
display page of the „CHARGE" menu.
00
NiCd Auto Mode
In parallel, the charger checks the balancer port of the active charging channel
Charge Mode
CH1 or CH2 and compares the number of cells of the connected battery with
AUTO
the default settings, whereupon corresponding messages are shown on the
Discharge Mode
NONE
display.
Balancer port is
not connected ...
0 0:00 :00
CH1
CH2
Then you have about five seconds - depending on the selected battery type -
CH AR GE
05:39:53
PM
to select or adjust other options, see below.
00
NiCd Auto Mode
Charge Mode
5
AUTO
Discharge Mode
NONE
Start Delay Time
00 :00 :0 0
CH1
CH2
20
Short description
Maximum cell voltage at constant charge (CV)
The default value, inherited from the „Profiles" menu to 1C, can be adapt-
ed within the „Maximum capacity" of the charge port rate and the charger
features, see display 2 of the menu „Settings" on page 43, in the range of
0.1 to a maximum of 30 A.
Setting range: 10 ... 80 ° C (Default: 50 ° C). If the temperature sensor is
connected, the charge process is stopped automatically when that tem-
perature is exceeded.
Setting range: 10 ... 150% in 5% increments, OFF (default value: 120%).
To avoid damage from overcharging, the charge stops when the limit is
exceeded.
Setting range: 10 ... 900 minutes in 5 minute increments OFF (default
value:
120 min). To avoid damage from overcharging, the charge stops when
the limit is exceeded.