Garmin GTN 625 Installation Manual page 107

Hide thumbs Also See for GTN 625:
Table of Contents

Advertisement

5.2.16.2 VOR/ILS Indicator Electrical Characteristics
5.2.16.2.1 Superflags
VOR/LOC SUPERFLAG
GLIDESLOPE SUPERFLAG
The output supplies not less than 320 mA with the output voltage not less than (AIRCRAFT POWER 
-2 VDC) when the flag is to be OUT OF VIEW. The output voltage with respect to ground is less than 250
mVDC when the flag is to be IN VIEW.
5.2.16.2.2 Deviation
VOR/LOC +LEFT
VOR/LOC +RIGHT
GLIDESLOPE +UP
GLIDESLOPE +DOWN
The deviation output is capable of driving up to three 1000 loads with150 mVDC 15 mVDC for full-
scale deflection, 0 mVDC 9.9 mVDC for LOC signal and 0 mVDC ± 10.14 mVDC for GS signal when
centered. The drive circuit provides for more than full-scale deflection with a maximum course deviation
output voltage of ±300 mVDC 30 mVDC.
5.2.16.2.3 TO/FROM
VOR/LOC +TO
VOR/LOC +FROM
The output is capable of driving up to three 200 meter loads. When indicating TO, the output is
+225 ±75 mVDC. When indicating FROM, output is -225 ±75 mVDC. When invalid information is
present (Flag IN VIEW) the TO/FROM output is 0 ±10 mVDC.
5.2.16.2.4 Flag
VOR/LOC +FLAG
VOR/LOC -FLAG
GLIDESLOPE +FLAG
GLIDESLOPE -FLAG
The Flag output is capable of driving up to three 1000 meter loads. When valid information is present
(Flag OUT OF VIEW) the Flag output is 375 ±80 mV DC. When invalid information is present (Flag IN
VIEW) the Flag output is 0 ±25 mV DC.
190-01004-02
Rev. F
Pin Name
Pin Name
Pin Name
Pin Name
Connector
Pin
P1004
15
P1004
38
Connector
Pin
P1004
5
P1004
6
P1004
34
P1004
55
Connector
Pin
P1004
1
P1004
2
Connector
Pin
P1004
3
P1004
4
P1004
32
P1004
53
GTN 625/635/650 TSO Installation Manual
I/O
Out
Out
I/O
Out
Out
Out
Out
I/O
Out
Out
I/O
Out
Out
Out
Out
Page 5-27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gtn 635Gtn 650

Table of Contents