Table B-2. Type 2 Output Sentence Format - Garmin GTN 625 Installation Manual

Hide thumbs Also See for GTN 625:
Table of Contents

Advertisement

Table B-2 describes the Type 2 output sentence item designator (id), sequence number (seq), waypoint
identifier (wpt), waypoint latitude (lat), waypoint longitude (lon), and magnetic variation at waypoint
(mvar) fields.
Field
Byte
1
id
2-3
seq
1
wpt
1-5
1
lat
2
3
1
2
lon
3
4
mvar
1-2
GTN 625/635/650 TSO Installation Manual
Page B-4

Table B-2. Type 2 Output Sentence Format

Format
7 6 5 4 3 2 1 0
x l a n n n n n
s d d d d d d d
x x m m m m m m
x h h h h h h h
s x x x x x x x
d d d d d d d d
x x m m m m m m
x h h h h h h h
Description
ASCII character 'w' (77 hex)
Two ASCII numeric characters representing route
sequence number of waypoint (01 to 31)
x
- undefined
l
- 1 if last waypoint in route
a
- 1 if active to waypoint
nnnnn
- route sequence number of waypoint
(unsigned binary)
Destination waypoint identifier (will be blank filled on
right if less than 5 characters in identifier)
s
- 0 (north) or 1 (south)
ddddddd
- latitude degrees (unsigned binary)
xx
- undefined
mmmmmm
- latitude minutes (unsigned binary)
x
- undefined
hhhhhhh
- hundredths of latitude minutes
(unsigned binary)
s
- 0 (east) or 1 (west)
xxxxxxx
- undefined
dddddddd
- longitude degrees (unsigned
binary)
xx
- undefined
mmmmmm
- latitude minutes (unsigned binary)
x
- undefined
hhhhhhh
- hundredths of latitude minutes
(unsigned binary)
Two's complement binary in 16ths of degrees.
Easterly variation is positive. MSB output first.
190-01004-02
Rev. F

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gtn 635Gtn 650