Fuse Block (Greensmaster 3400 with Serial Number Below 312000000)
The fuse block on Greensmaster 3400 machines is at-
tached to the frame under the operator seat (Fig. 33).
In addition to the fuses in the fuse block, a 50 amp
maxi--fuse is included in the wire harness. This fuse pro-
tects the engine cooling fan circuit and resides in a fuse
holder under the right side cover next to operator seat.
Fuse Identification and Function
Use Figure 34 to identify each individual fuse and its cor-
rect amperage. Fuses for Greensmaster 3400 ma-
chines Greensmaster 3400 machines with a serial
number below 312000000 have the following function:
Right Fuse 1 (2 Amp): Protects TEC logic and igni-
tion switch power supply circuits.
Right Fuse 2 (7.5 Amp): Protects TEC output power
supply for start relay, engine run solenoid, fuel pump,
glow relay, glow plug indicator light and console diag-
nostic light.
Right Fuse 3 (7.5 Amp): Protects TEC output power
supply for fan relay, cutting reels engage solenoid, lift
enable solenoid (S1) and lift/lower solenoid (S2).
Right Fuse 4 (7.5 Amp): Protects TEC output power
supply for lift solenoids S3 (front cutting units), S4
(center cutting unit) and over temperature indicator
light.
Left Fuse 1 (10 Amp): Protects power supply for
hour meter, low engine oil pressure indicator light, al-
ternator and proximity switches (parking brake, neu-
tral and mow).
Left Fuse 2 (15 Amp): Protects power supply for
start relay and solenoid.
Left Fuse 3 (15 Amp): Protects power supply for op-
tional Turf Defender
optional lights.
Left Fuse 4: Not used.
Fuse Testing
Make sure that ignition switch is OFF and key is re-
moved from switch. Remove fuses from the fuse block
for testing. Fuse should have continuity between fuse
terminals.
Electrical System
TM
Leak Detector system and
1. Seat base (raised)
LEFT
RIGHT
15A
15A
10A
Page 6 - - 32
1
2
Figure 33
2. Fuse block
4
7.5A
LIGHTS
3
7.5A
LEAK DETECTOR
15A
2
7.5A
STARTER
1
2A
15A
RUN
10A
Figure 34
Greensmaster 3300/3400
LIFT REEL
OVER TEMP
7.5A
REEL ENGAGE
LIFT/LOWER
FAN
7.5A
START/RUN
DIAG. LIGHT
GLOW
7.5A
TEC LOGIC
POWER
2A