Retrieving Fault Codes
All machine fault codes are retained in the TEC control-
ler memory. The three (3) most recent fault codes that
have occurred within the last forty (40) hours of opera-
tion can be retrieved using the diagnostic light. To re-
trieve these fault codes from the controller memory,
perform the following switch sequence:
1. Operator seat should be UNOCCUPIED.
2. Place functional control lever in the TRANSPORT
position.
3. Make sure that backlap valve on mow control man-
ifold is in the MOW position.
4. Move and hold joystick in the RAISE position.
5. Turn ignition switch to the RUN position.
6. Monitor the diagnostic light for fault code(s).
NOTE: Once the diagnostic light begins to display fault
codes, the joystick can be released.
Fault Code (Lamp Flashes)
2 -- 1
2 -- 9
3 -- 1
3 -- 2
3 -- 7
3 -- 9
4 -- 3
4 -- 7
5 -- 2
5 -- 4
5 -- 5
5 -- 6
5 -- 7
6 -- 4
6 -- 7
7 -- 1
7 -- 4
7 -- 6
7 -- 8
8 -- 1
Greensmaster 3300/3400
Fault codes displayed by the diagnostic light consist of
a two digit number. Fault codes are listed in the chart be-
low. There will be a one (1) second pause between the
first and second digit of a code. Up to three (3) fault
codes retained in controller memory will be displayed by
the diagnostic light in order from the most recent fault to
the oldest fault. If there are multiple faults in controller
memory, there will be a three (3) second pause between
codes. The fault codes will continually repeat after a five
(5) second pause until the ignition key is turned off.
If there are no faults that have occurred within the last
forty (40) hours of operation, the diagnostic light will
flash continuously after performing the above fault re-
trieval switch sequence.
If a fault code is not retrieved from the controller memory
within forty (40) hours of machine operating time, the
fault cannot be retrieved from controller memory using
this procedure. If necessary, contact your Toro distribu-
tor to retrieve older fault codes.
Controller has been replaced causing machine identification to be in error
Excessive engine temperature has caused engine shutdown
Current to fan relay is excessive
Optional hydraulic oil temperature sensor is faulty (GR3400)
Current to console high temperature warning light is excessive (GR3400)
Engine alternator voltage output is excessive
Right fuse 2 (7.5 amp) for TEC outputs is faulty
Right fuse 3 (7.5 amp) for TEC outputs is faulty
Right fuse 4 (7.5 amp) for TEC outputs is faulty
Current to leak detector alarm (GR3300) or glow relay (GR3400) is excessive
Main power relay is faulty
Current to solenoid coil S1 (lift/lower manifold) is excessive
Current to solenoid coil S2 (lift/lower manifold) is excessive
Current to solenoid coil S3 (lift/lower manifold) is excessive
Current to solenoid coil S4 (lift/lower manifold) is excessive
Current to solenoid coil PRV (mow manifold) is excessive
Current to start relay is excessive
Page 6 - - 9
Fault Description
TEC controller is faulty
Coolant sensor is faulty
TEC controller is faulty
Electrical System