Toro Greensmaster TriFlex 3300 Service Manual page 101

Hide thumbs Also See for Greensmaster TriFlex 3300:
Table of Contents

Advertisement

The mow circuit gear pump flow test should be per-
formed to make sure that the mow circuit has adequate
hydraulic flow.
Procedure for Mow Circuit Gear Pump Flow Test:
1. Make sure hydraulic oil is at normal operating tem-
perature by operating the machine for approximately ten
(10) minutes.
2. Park machine on a level surface with the cutting units
lowered. Make sure engine is off and the parking brake
is engaged. Make sure the hydraulic tank is full.
CAUTION
Prevent personal injury and/or damage to equip-
ment. Read all WARNINGS, CAUTIONS and Pre-
cautions for Hydraulic Testing at the beginning
of this section.
3. Thoroughly clean junction of hydraulic hose and dis-
charge fitting of front gear pump section (Fig. 27). Dis-
connect hose from pump fitting.
4. Install hydraulic tester (pressure and flow) in series
with the front gear pump section and the disconnected
hose. Make sure that tester flow arrow points from the
pump discharge and toward the disconnected hose.
Also, make sure flow control valve on the tester is
fully open.
5. Make sure backlap lever on the mow control man-
ifold is in the mow position and reel speed knob (FC) is
set to highest speed setting (fully open).
CAUTION
Do not engage the cutting units when performing
this test.
6. After hydraulic tester has been connected, start en-
gine and run at low idle speed. Check for hydraulic leak-
age and correct before proceeding with test.
Greensmaster 3300/3400
7. Move throttle so engine is running at high idle speed.
IMPORTANT: Do not fully restrict oil flow through
tester. In this test, the flow tester is positioned be-
fore the circuit relief valve. Pump damage can occur
if the oil flow is fully restricted.
8. Watch pressure gauge carefully while slowly closing
the flow control valve on the tester until 2000 PSI (138
bar) is obtained.
9. Flow gauge reading for a gear pump in good condi-
tion should be approximately 6.9 GPM (26 LPM). Re-
cord test results.
10.Open control valve on tester and shut off engine.
11. If flow was less than 6.1 GPM (23.1 LPM) or a pres-
sure of 2000 PSI (138 bar) cannot be obtained, check
for restriction in the pump intake line. If line is not re-
stricted, remove gear pump and repair or replace as
necessary.
12.When testing is complete, disconnect tester from
gear pump fitting and hydraulic hose. Connect hose to
pump fitting.
13.Adjust reel speed knob (FC) on mow control man-
ifold to original setting.
2
GR3300 GEAR PUMP SHOWN
1. Gear pump
Page 5 - - 49
1
Figure 27
2. Front section fitting
Hydraulic System

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greensmaster triflex 34000451004520

Table of Contents