Low Ice Making Capacity - Remote

Problem
Long freeze cycle
Long Harvest Cycle
False bin full signal
Likely Cause
Dirty condenser
Hot ambient
Water leak
Water inlet valve leaks through
Low on refrigerant
Incorrect superheat
Fan(s) cycle on and off
Dirty evaporator
No harvest assist
Bridge thickness too big
Machine in very cool ambient
Ice jammed in between curtain
and sump
Curtain does not close correctly
September 2006 Page 55
Probable Solution
Clean condenser
Check condenser inlet temp.
Check purge valve, check
curtain
Check inlet valve
Add refrigerant, if cycle time
drops, check for leak
Check evaporator superheat, if
significantly low or high,
replace TXV
Check pressures fans cycle at.
Replace fan pressure switch if
too low
De-scale water system
Check harvest assist solenoid
Check and adjust bridge
thickness
Increase room temperature
Clear ice away
Check curtain for proper swing

Hide quick links: