Clean And Sanitize Ice Making System - Scotsman CU50PA-1 Installation And User Manual

Cube ice machine
Table of Contents

Advertisement

Clean and Sanitize Ice Making System

Winterizing
1. Clean the ice making system.
2. Open the door and push and release the
On/Off switch to turn the machine off.
3. Turn off the water supply.
4. Drain the water reservoir by removing the
rubber cap under the reservoir - it's near the
back wall of the ice storage bin.
5. Disconnect the incoming water line at the inlet
water valve.
6. Open the door, push and release the on/off
switch to turn the machine on.
7. Blow air through the inlet water valve until
water stops flowing out; a tire pump could do
the job.
8. Drain pump models should have about
1/2 gallon of RV antifreeze (propylene glycol)
poured into the ice storage bin drain.
Note: Automotive antifreeze must NOT be used.
9. Switch off and unplug the machine.
Pour Scale
Remover Here
June 2012
Page 14
Installation and User's Manual
Remove Scale
1. Remove and discard all ice.
2. Press and HOLD the On/Off button in for
3 seconds until the Green light goes out.
3. Press and HOLD the both the Clean-Reset
and On/Off buttons for 5 seconds. The Time
to Clean light will blink on and off.
4. Pour 8 ounces of Scotsman Ice Machine Scale
Remover (available from a local Scotsman
Distributor or Dealer) into the ice machine
reservoir.
5. Operate the machine for about ½ hour.
6. Push and release the On/Off switch. The
machine will begin to flush out the cleaning
solution.
7. Operate the machine for another ½ hour.
8. Push and release the On/Off switch. The
machine will stop the cleaning process.
9. Pour a gallon of hot (95°F. - 115°F.) water into
the bin to flush out the drain.
CU50