General Installation - Remote
Product Description and Electrical Requirements
- See spec sheet or User's Manual for Minimum Circuit Ampacity or Maximum Fuse SIze
Dimensions
w" x d" x h"
22 x 24 x 23
same
30 x 24 x 23
same
same
30 x 24 x 29
same
same
same
48 x 24 x 29
same
same
same
same
same
** ERC211 has two circuits, when two C0522s or C0530s are connected to it, fan motor relay
kit KCMR120 must be used to control the fan motor.
Ratings include the remote condenser motor, as it is designed to be powered by the ice
machine. If connecting remote condenser independently of the ice machine, use the
information on the condenser's dataplate for fuse and wire sizes.
Table notes: Medium cube models have the same electrical characteristics as Small. Series
revision code omitted. All the listed condensers include a headmaster valve.
Model
C0522SR-1
same
C0530SR-1
same
C0630SR-32
C0830SR-32
C0830SR-3
C1030SR-32
C1030SR-3
C1448SR-32
C1448SR-3
C1848SR-32
C1848SR-3
C2148SR-32
C2148SR-3
September 2006 Page 10
Electrical
115/60/1
same
115/60/1
same
208-230/60/1
208-230/60/1
208-230/60/3
208-230/60/1
208-230/60/3
208-230/60/1
208-230/60/3
208-230/60/1
208-230/60/3
208-230/60/1
208-230/60/3
Use condenser
ERC111-1
ERC211-1**
ERC111-1
ERC211-1**
ERC311-32
ERC311-32
ERC311-32
ERC311-32
ERC311-32
ERC311-32
ERC311-32
ERC611-32
ERC611-32
ERC611-32
ERC611-32