Adjustments

Bridge Thickness - For the Service Tech
Only
Push and hold Off till the machine stops.
Access ice thickness sensor.
Check gap between metal tip and evaporator
grid. Small cube standard gap is 3/16 inch,
medium cube standard gap is 7/32 inch. To
set, place a 3/16" (small cube) or 7/32"
(medium cube) drill bit between sensor tip
and evaporator to check. Adjust gap using
adjustment screw.
Restart unit and check ice bridge. Repeat as
needed
Caution: Do not make the bridge too thin or the machine will not harvest properly. Bridge thickness
adjustments are not covered by warranty.
Water purge setting
The water purge is factory set to Automatic. The setting can be changed to one of 5 manual
settings or left on automatic.
purge
1 -
setting
Minimum
RO water
or
Water
equivalent,
Type
TDS less
than 35
To set:
Switch the machine OFF by holding the Off button in until a number or the letter A shows on
the display.
Press and release the On button repeatedly until the number on the display corresponds to the
desired setting.
Press and release the Off switch again to return to the normal control state.
2 -
3 -
Moderate
Standard
Low TDS
Setting
non - RO
for typical
water
water
September 2006 Page 20
Adjustment
Screw
Gap
4 -
5 -
Heavy
Maximum
Very hHigh
High
TDS water,
TDS
greater
water
than 256
A - Automatic
Any with
conductivity
not less than 10
microSiemens/
cm