General Installation - Air or Water Cooled

Location Limitations:
The product is designed to be installed indoors, in a controlled environment. Air cooled models
discharge very warm air into the room out the back. Space must be allowed at the left side and
back for air intake and discharge. Water cooled models discharge warm water into the
building's drain. Space needs to be provided on both sides and above for service access.
Space Limitations
Note: Although the machine will function, ice capacity of air cooled machines will be significantly reduced
with minimal clearance at the sides, back and top. Some space is recommended for service and
maintenance purposes on all models.
6" of space at the sides and back are required for adequate operation. To get the most
capacity, locate the machine away from heat producing appliances and heating ducts.
22 and 30 inch wide models: Airflow is in the left side, out the back (as viewed from the front).
48 inch wide models: Air flow is in the front and left side and out the back.
Environmental Limitations
Air temperature
Water temperature
Water pressure
Power supply – acceptable voltage ranges
115 volt model
208-230 volt model
Warranty Information
The warranty statement for this product is provided separately from this manual. Refer to it for
applicable coverage. In general warranty covers defects in material or workmanship. It does
not cover maintenance, corrections to installations, or situations when the machine is operated
in circumstances that exceed the limitations printed above.
Minimum
o
50
F.
o
40
F.
20 psi
Minimum
104 volts
198 volts
September 2006 Page 4
Maximum
o
100
F.
o
100
F.
80 psi
Maximum
126 volts
253 volts