BATTERY PACK
Figure 8.3 Intellifi re Pilot Ignition (IPI) Wiring Diagram with Wall Switch or Thermostat
NOTE: 1. Ignition module, valve, pilot, and
wall switch operate on 3 volts. 110-120 VAC
is required at junction box unless equipped
with battery back-up.
BATTERY PACK
PLUG IN
Figure 8.4 Intellifi re Ignition Wiring Diagram with Remote Receiver
Heat & Glo • SL-550/750TR-E, SL-550/750/950TR-IPI-E Installation Manual • 2118-910 Rev. C • 4/16
IGNITION MODULE 3 VAC
TRANSFORMER
3 VAC
PLUG IN
WIRES
(TO BROWN)
WIRE ASSEMBLY
TRANSFORMER
3 VAC
PLUG IN
REMOTE
INTERMITTENT PILOT IGNITOR
I
S
NOTE: 1. Ignition module, valve, pilot, and
wall switch operate on 3 volts. 110-120 VAC
is required at junction box unless equipped
with battery back-up.
WHITE
ORANGE
GROUND TO
FIREPLACE
CHASSIS
VALVE
INTERMITTENT
IGNITION
PILOT IGNITOR
MODULE 3 VAC
I
S
ORANGE
WHITE
GROUND TO
FIREPLACE
CHASSIS
WIRES
(TO BROWN)
VALVE