Maintenance

General

Have the fireplace and installation inspected yearly. The inspection
must include, but is not limited to, the following:
A visual check of the entire vent system and termination.
An inspection of the explosion relief flappers and the door
gaskets to ensure a proper seal.
An inspection of the burner / pilot assembly, vent run, and
primary air openings.
An inspection of the gas valve, gas components, and pilot
flame. For your convenience a 1/8" manifold pressure tap
is supplied on the gas valve for a test gauge connection
Inspection of all equipment; fans, thermostats, etc.
For Natural Gas this appliance requires a minimum inlet
pressure of 5.5" W.C. and a manifold pressure of 3.5" W.C.
For Propane Gas this appliance requires a minimum inlet
pressure of 11" W.C. and a manifold pressure of 10" W.C.
Always keep the fireplace area clear and free of combustible
materials, as well as gasoline and other flammable vapours
and liquids.
Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
Inspection of glass doors and screens for damage and
proper installation.

Cleaning

When the fireplace is first activated, there may be some smoke and
a visible film may be left on the glass. This is a normal condition,
and is the result of curing of protective coatings on new metal.
Glass must be cleaned periodically to remove any film
(which is a normal by-product of combustion) which may
be visible. Film can easily be removed by removing the
door, as shown on Page 24. Handle the door carefully, and
clean it with nonabrasive glass cleaners. One of the most
effective products is Kel Kem.
Silicone seals on inner door during initial firing will "off gas",
leaving a visual deposit of a white substance on combustion
chamber walls. This can easily be removed from the chamber
walls using normal household products.
Use a vacuum cleaner keep the control compartment, burner,
and firebox free from dust and lint.
NOTICE
Do not use ammonia based or abrasive cleaners on the glass, they will permanently
etch the surface. Use an approved gas fireplace glass cleaner such as Kel-Kem or
White off.
Page 36
Maintenance
Pilot Burner Adjustment.
1. Locate Pilot Adjustment Screw. (See figure 29)
2. Adjust pilot screw to provide properly sized flame as shown.
3. After installing or servicing, leak test with a soap solution with
main burner on. Coat pipe and tubing joints, gasket etc. with
soap solution. Bubbles indicate leaks. Tighten any areas where
the bubbles appear until the bubbling stops completely.
Figure 29. 'Hi-Lo' Adjustment on the SIT Proflame 2 gas valve.
Manifold Pressure
Test Connection
Inlet Pressure
Test Connection
Pilot Adjustment Screw
XG0216 - 160215.1