Montigo PL38DF Installation & Maintenance Manual page 34

Pl series
Table of Contents

Advertisement

PL38DF* Indoor Gas Fireplace
Disabling Thermostat
Some jurisdictions and bedroom installations require the
thermostat to be disabled.
1. Partially take out one battery, see Figure 28j.
2. Insert the battery while holding down the thermostat button.
The remote screen will display 'Clr' while the button is held
down. See Figure 28k.
3. To enable thermostat repeat steps 1-2. The remote screen
will display 'set' while the thermostat button is held down.
Figure 28j.
Figure 28k.
Page 34
Operation
Fan Speed Control (OPTIONAL)
The fireplace is equipped with optional hot air circulating fans.
The speed of the fans can be controlled by the Proflame system.
The fan speed can be adjusted through six (6) speeds. To
activate this function use the Mode Key, see Figure 28, to index
to the fan control icon, see Figure 28l. Use the Up/Down Arrow
Keys to turn on, off, or adjust the fan speed. A single "beep" will
....
confirm reception of the command.
.....
Figure 28l. Fan Speed Control
XG0216 - 160215.1