Section 5: Installing the Gas Line

Section 5-1: FUEL CONVERSION

Verify that your fireplace is compatible with your
n
available gas type. (Natural Gas or Propane shown
by "N" or "L" in your model number
If gas type is not compatible, contact your local
n
Montigo representative.
Conversion kits must be installed by a qualified
n
service technician.

Section 5-2: GAS PRESSURE

Optimum appliance performance requires proper
n
input pressures.
Gas line sizing requirements will be determined in
n
ANSI Z223.1/ NFPA 54 National Fuel Gas Code in the
USA and CAN/CGA B149.1 in Canada.
Pressure requirements are:
Gas Pressure
Minimum inlet pressure
Manifold pressure
The manifold outlet pressure is set from the factory
n
to the appropriate pressure but should be verified.
To check pressures, control valves have a provision
n
to remove a 1/8" N.PT. plug to be fitted with a hose
barb.
Montigo requires a service shut off valve be located
n
in an accessible location to isolate the gas supply.
Only install gas shut-off valves approved for use
n
by the state, province, or other governing body in
which the fireplace is being installed.

Section 5-3: GAS CONNECTION

See Figure 22 for location of gas line access.
n
Flexible gas connectors must not exceed 3 feet in
n
length, unless allowable within local regulations.
Connect incoming gas line to the 1/2"or 3/8" gas
n
inlet port.
Check appliance connection, valve and valve train
n
under normal operating pressure with a commercially
available leak check solution.
DO NOT USE A FLAME OF ANY KIND TO TEST FOR LEAKS.
XG0216 -160215.1
Installation
Natural Gas
Propane
5.5in. w.c.
11in. w.c.
3.5in. w.c.
10in. w.c.
NOTICE
When pressure testing the fireplace, Gas line, and input system follow the appropriate
local codes or your area. DO NOT connect the fireplace to pressures in excess of
1/2lb. This will damage the gas control valve.
1
1
4 "
2"
8 1/2
Figure 22. Gas line access.
WARNING
When installing the replace - gas lines, ttings, accesso-
ries or any other objects cannot impede the proper
movement of the door buckles.
WARNING:
An inspection of the explosion relief flappers and door MUST be made
prior to lighting the fireplace. A faulty seal on the door gasket and/or
explosion ports will result in products of combustion leaking into the
living space and may result in carbon monoxide poisoning.
PL38DF* Indoor Gas Fireplace