Checking The Fl Ue Expulsion Pipe; Combustion Analysis Check; Checking The Condensate Drain Pipe; 9.10 Visual Inspection Of Appliance - Biasi Activ A 250V User Manual And Installation Instructions

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Table of Contents

Advertisement

9.7
Checking the fl ue expulsion
pipe
Have the integrity of the fl ue outlet pipe air
intake pipe, checked periodically, at least
once a year. For all the above maintenance
operations it is advisable to call an approved
Service Engineer.
9.8

Combustion analysis check

It is recommended that a combustion analy-
sis check is made. Remove the plug as in-
dicated in Fig. 9.7 and carry out combustion
analysis check and adjustment if necessary
as described in the section Gas valve - Ad-
justment of the Service manual.
Flue analysis
points
Fig. 9.7
9.9
Checking the condensate
drain pipe
The condensate drain pipe 25 ( Fig. 9.8 )
does not require any particular mainte-
nance but just check:
• That no solid deposits have formed, if so
remove them.
• That the condensate drain piping is not
clogged.
Unscrew the plug to clean inside the pipe.
- 76 -
MAINTENANCE
Fig. 9.8
Removal
• Unscrew the screws T and remove the
plate S ( Fig. 9.9 ).
• Remove the forks R and remove the con-
densate trap 25 moving it downwards ( Fig.
9.8 ).
Fig. 9.9

9.10 Visual inspection of appliance

Visually inspect all water joints, seals and
connections for any evidence of leakage
and retighten, grease or replace them as
necessary.
T
R
25