Technical Data Activ A 25Ov - Biasi Activ A 250V User Manual And Installation Instructions

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Table of Contents

Advertisement

4.6

Technical data Activ A 25OV

Heat input
(A)
Nominal net
Nominal gross
(B)
Minimun net
(A)
(B)
Minimun gross
Useful output
Maximun
Minimun
Maximun condensing
Minimun condensing
- 30 -
TECHNICAL INFORMATION
kW
25,0
BTU/h
85297
kW
27,8
BTU/h
94679
kW
6,4
BTU/h
21836
kW
7,1
BTU/h
24238
kW
24,5
BTU/h
83591
kW
6,3
BTU/h
21495
kW
25,6
BTU/h
87344
kW
6,8
BTU/h
23201
Central heating
Min/Max fl ow temperature settings*°C
Maximum pressure
Minimum pressure
Pressure loss (in 1000 l/h)
(c)
Seasonal effi ency G20
(c)
Seasonal effi ency G31
* to the minimum useful output
(A)
referred to the net calorifi c value at 15 °C and
1013,25 mbar: G20 = 34,02 MJ/m
kg
(B)
referred to the gross calorifi c value at 15 °C and
1013,25 mbar: G20 = 37,78 MJ/m
kg
(C)
The value is used in the UK Government's Standard
Assessment Procedure (SAP) for energy rating
of dwellings. The test data from which it has been
calculated have been certifi ed by a notifi ed body.
(D)
Values subject to tolerance
Gas supply pressures
Gas
Nom
Natural G20
Min
Max
Nom
Propane G31
Min
Max
25 - 85
kPa
250
bar
2,5
kPa
30
bar
0,3
Pa
11000
mbar
110
band
A
%
90,3
band
A
%
91,3
3
- G31 = 46,34 MJ/
3
- G31 = 50,37 MJ/
Pa
mbar
2000
20
1700
17
2500
25
3700
37
2500
25
4500
45

Advertisement

Table of Contents
loading

Table of Contents