Technical Data Activ A 15Ov - Biasi Activ A 250V User Manual And Installation Instructions

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Table of Contents

Advertisement

4.4

Technical data Activ A 15OV

Heat input
(A)
Nominal net
Nominal gross
(B)
Minimun net
(A)
(B)
Minimun gross
Useful output
Maximun
Minimun
Maximun condensing
Minimun condensing
- 26 -
TECHNICAL INFORMATION
kW
15,0
BTU/h
51178
kW
16,7
BTU/h
56807
kW
5,9
BTU/h
20130
kW
6,5
BTU/h
22344
kW
14,7
BTU/h
50154
kW
5,8
BTU/h
19789
kW
15,5
BTU/h
52884
kW
6,3
BTU/h
21495
Central heating
Min/Max fl ow temperature settings*°C
Maximum pressure
Minimum pressure
Pressure loss (in 1000 l/h)
(c)
Seasonal effi ency G20
(c)
Seasonal effi ency G31
* to the minimum useful output
(A)
referred to the net calorifi c value at 15 °C and
1013,25 mbar: G20 = 34,02 MJ/m
kg
(B)
referred to the gross calorifi c value at 15 °C and
1013,25 mbar: G20 = 37,78 MJ/m
kg
(C)
The value is used in the UK Government's Standard
Assessment Procedure (SAP) for energy rating
of dwellings. The test data from which it has been
calculated have been certifi ed by a notifi ed body.
(D)
Values subject to tolerance
Gas supply pressures
Gas
Nom
Natural G20
Min
Max
Nom
Propane G31
Min
Max
25 - 85
kPa
250
bar
2,5
kPa
30
bar
0,3
Pa
12000
mbar
120
band
A
%
90,0
band
A
%
91,1
3
- G31 = 46,34 MJ/
3
- G31 = 50,37 MJ/
Pa
mbar
2000
20
1700
17
2500
25
3700
37
2500
25
4500
45

Advertisement

Table of Contents
loading

Table of Contents