due of the fan:
Useful static pressure at
nominal heat input
Activ A 12OV
Activ A 15OV
Activ A 20OV
Activ A 25OV
Roof fl ue exhaust kit ( Fig. 6.12 )
Coaxial pipe Ø 80/125 mm with a nominal
height of 0.96 m.
This kit exhausts directly to the roof.
Type C
33
Ø 125
Fig. 6.12
Extensions are available for reaching the
maximum height.
Its maximum height with extension is 10 m.
Bends of Ø 80 mm at 90° and at 45° are
available that reduce the maximum total
length of the pipes by:
For the bend of 45° loss
For the bend of 90° loss
Pluming kit ( Fig. 6.13 )
Co-axial ø 60/100 mm + vertical part ø 60
mm (fl ue outlet).
This kit allows the combustion air to be
INSTALLATION
sucked up and expel the burnt gases di-
rectly to the outside through a telescopic
co-axial fl ue (450-950 mm).
90° =--- 0,85 m
45° =--- 0,65 m
Fig. 6.13
90°
In the last section, the fumes are expelled
through a vertical section.
Extensions and elbows can be added to ex-
45°
tend the kit's length.
Maximum equivalent length "a+b" ( Fig.
6.13 ) of 15 metres can be achieved utilising
extensions.
Each additional elbow reduces the overall
acceptable length of the fl ue system as fol-
lows:
45° (60/100 mm) reduce length by 0,5 m.
90° (60/100 mm) reduce length by 1 m.
45° (60 mm) reduce length by 0,65 m.
90° (60 mm) reduce length by 0,85 m.
0,5 m
1 m
6.9
• Unscrew screws " N " and remove the front
panel " O " by pulling it and pushing it to-
wards the top so that it is freed from the
top housing Fig. 6.14 .
ø 60 mm
45° =--- 0,5 m

Electric connection

90° =--- 1 m
ø 60/100 mm