Sp4-Xxx (Scanner) - Ricoh K-C3 Service Manual

Machine code b245/b268/b269/b276/b277
Hide thumbs Also See for K-C3:
Table of Contents

Advertisement

B245/B276/B277/B268/B269 Service Manual
[0 = No / 1 = Yes]
Selects whether the ID sensor is or is not used for toner density control. This
2927 1
value should normally be left at "1". If the value is "0", dirty background may
occur after long periods of non-use.
Toner End Clear
2928
Clears the toner end condition without adding new toner. The following are
cleared:
Toner end indicator (goes out)·
Toner near-end counter
2928 1
Toner near-end level
This function should generally not be used. If you clear the toner end condition
without adding new toner, there is a risk that the drum may eventually begin to
attract carrier after many more copies are made and toner runs out. This
attracted carrier may damage the drum.
Vref Limits
2929*
Adjust the upper or lower Vref limit.
2929 1 Upper
2929 2 Lower
ID Sensor Detection Temperature [30 ~ 90 / 30 / 1 C/step]
2994*
While the machine is recovering from an energy saver mode, or while the
2994 1
machine starts, the controller ignores the ID-sensor signals if the fusing
temperature is at the specified value or higher.
Transfer Roller Cleaning
2996*
Selects whether the transfer roller is cleaned before each copy job. Set this to
"1" if dirty background is appearing on the reverse side of the first page of
2996 1
copy jobs. Note that this will increase the time required to generate the first
copy. If the setting is "0", the transfer roller is never cleaned (
Toner Density Sensor Standard
2997*
Voltage
Main Scan Magnification
2998*
Adjusts the magnification along the main scan direction, for all print modes
2998 1
(copy, printing). The specification is 100 ± 1.0% (

SP4-XXX (Scanner)

Sub-Scan Magnification (Scanner)
4008*
Adjusts the actual sub-scan direction scanning magnification. The higher the
4008 1
setting, the lower the scanner motor speed.
Main Scan Magnification (Scanner)
4009*
4009 1 Adjusts the magnification along the main scan direction, for scanning.
[0.50 ~ 3.50 / 3.20 / 0.01V/step] DFU
[0.50 ~ 3.50 / 0.70 / 0.01V/step] DFU
[0 / 2.5 / 5/ 0.01V/step] DFU
[–0.5 ~ +0.5 / 0.0 / 0.1%/step]
[-0.9 ~ +0.9 / 0.0 / 0.1%/step]
[–0.9 ~ +0.9 / 0.0 / 0.1%/step]
18-Jan-06
p.228).
p.111).
141

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B245B268B277B276B269

Table of Contents