B245/B276/B277/B268/B269 Service Manual
Controller data
- Exceptions -
SP 5801 2 (basic machine) and SP 5998 1 (GDI machine) clears most of the settings and
counters stored in the NVRAM on the BICU (the values return to their default values).
However, the following settings are not cleared:
SP 5807 (Area Selection)
SP 5811 1 (Serial Num Input [Code Set])
SP 5811 3 (Serial Num Input [ID2 Code Display])
SP 5812 1 (Service TEL [Telephone])
SP 5812 2 (Service TEL [Facsimile])
SP 5907 (Plug & Play)
SP 7 (Data Log)
SP 8 (History)
Use SP 5802 2 (basic machine) or SP 5998 1 (GDI machine) after you have replaced the
BICU NVRAM or when the BICU NVRAM data is corrupted. When the program ends
normally, the message "Completed" shows. When you have replaced the controller NVRAM
or when the controller NVRAM data is corrupted, use SP 5801 1. The message is the same
as the basic machine.
- With Flash Memory Card
1.
Upload the NVRAM data to a flash memory card (
2.
Print out all SMC data lists (
Be sure to print out all the lists. You have to manually change the SP settings if
the NVRAM data upload ends abnormally.
3.
Select SP 5801 2.
4.
Press the OK key.
5.
Select "Execute." The messages "Execute?" followed by "Cancel" and "Execute"
shows.
Controller
SP 5801-xxx
p.172).
than controller
data
SCS, IMH, MCS,
Copier
application,
Printer
application,
Scanner
application, Web
service/network
application, NCS,
R-Fax, DCS, UCS
p.165).
18-Jan-06
160