ASSEMBLY/SET-UP INSTRUCTIONS
9. Open the bypass valves X on each pump
by rotating handle counter-clockwise two
revolutions.
10. Cut and remove wire ties S from the control
levers A. Place the control levers in the neutral
position in the control panel.
11. Assemble tracking control rod assembly.
Run wing nut and jam nut all the way on the
lower control rod. Thread both the lower and
upper rods 1/2 way into the turnbuckle.
6
EC
Hydro
Midsize