Chapter 3
- Be sure not to disassemble the laser / scanner unit as it needs adjustment.
- When holding the laser / scanner unit, be sure not to touch the laser mount
block [1] and the lens block [2].

3.3 IMAGE FORMATION SYSTEM

3.3.1 Developing Estrangement Solenoid

3.3.1.1 Preparation for Removing the Developing
Estrangement Solenoid
/ i-SENSYS LBP5360 / i-SENSYS LBP5300
1) Detach the rear cover. (page 3-1)[Removing the Rear Cover]
2) Remove the fixing assembly. (page
Assembly]
3) Detach the upper cover. (page 3-2)[Removing the Upper Cover]
4) Detach the right cover. (page 3-1)[Removing the Right Cover]

3.3.1.2 Removing the Developing Estrangement Solenoid

/ i-SENSYS LBP5360 / i-SENSYS LBP5300
1) Remove the claw [2] and move the cable guide [1] to the left.
2) Remove the plate [1].
- 3 screws [2]
3) Disconnect the 2 connectors and free the cable from the wire saddle [1].
3-14
F-3-97
3-25)[Removing the Fixing
F-3-98
F-3-99
4) Remove the developing estrangement drive unit [1].
- 3 screws [2]
0014-4824
5) Detach the sheet metal [1].
- 3 screws [2]
0014-4826
6) Remove the developing estrangement solenoid [1].
- 2 screws [2]
3.3.1.3 Points to Note when Attaching the Developing
Estrangement Solenoid
/ i-SENSYS LBP5360 / i-SENSYS LBP5300
Alignment of Developing Estrangement Drive Unit
1. Alignment of Developing Estrangement Drive Unit in Assembling
Rotate the gear [2] of the developing estrangement drive unit[1] to the
direction of the arrow, and align the solenoid claw [3] with the position
of the cut-off in the gear (home position).
F-3-100
F-3-101
F-3-102