10. If you have other options to install or remove, do so now; otherwise, go to
Attention: When you restart the server, the system displays a message indicating that
the memory configuration has changed.
54
IBM® xSeries 350: User's Reference
Make sure that the retaining clips are in the closed position. If a gap exists
between the DIMM and the retaining clips, the DIMM has not been properly
installed. In this case, open the retaining clips and remove the DIMM; then,
reinsert the DIMM.
Error LEDs
Memory slot 5
Repeat steps 3 through 7 for each additional DIMM that you install.
Install the memory-board assembly:
a.
Hold the memory board assembly, and align it into the card guides and over
the memory-board connector.
Note: When you insert the memory board assembly into the connector, press
on the flat metal projection on the board.
b. Insert the memory board assembly into the connector.
"Installing the server top cover and bezel" on page 62.
If you installed additional memory, start the Configuration/Setup Utility
program and select Save Settings.
If you just replaced a failed DIMM, you must start the Configuration/Setup
Utility program, select Advanced Setup, select Memory Settings, highlight the
connector or bank of connections that you want to enable, and then select Enable.
In some memory configurations, the 3-3-3 beep code might sound during POST
followed by a blank display screen. If this occurs and the Boot Fail Count feature
in the Start Options of the Configuration/Setup Utility is set to Enabled (its
default setting), you must restart the server three times to force the system BIOS
to reset the memory connector or bank of connectors from Disabled to Enabled.
Memory slot 1
Memory slot 13
Memory slot 9
Error LEDs