Features And Specifications - IBM eserver xSeries 350 User Reference Manual

Hide thumbs Also See for eserver xSeries 350:
Table of Contents

Advertisement

Features and specifications

Microprocessor:
Intel® Pentium® III Xeon™
32 KB level-1 cache
1 MB or 2 MB Level-2 cache
depending upon model
100 MHz front-side bus (FSB)
Support for up to four
microprocessors
Memory:
Maximum: 16 GB
Type: ECC, SDRAM,
registered DIMMs
Slots: 4-way interleaved, 16
slots
Drives standard:
Diskette: 1.44 MB
CD-ROM: 40X IDE
Expansion bays:
Hot-swap drives: Three standard
slim-high, three optional slim-high
Active PCI expansion slots:
One 33 MHz/32-bit
Three 66 MHz/64-bit
Two 33 MHz/64-bit
Hot-swap power supplies:
270 W (115-230 V ac)
Minimum: One
Maximum: Three
Redundant cooling:
Six hot-swap fans
Video:
S3 video controller
Compatible with SVGA and
VGA
8 MB video memory
2
IBM® xSeries 350: User's Reference
The following table provides a summary of the features and specifications for your
xSeries 350 server.
Table 1. Features and Specifications.
Size (4 U)
Height: 178 mm (7 in.)
Depth: 711.2 mm (28 in.)
Width: 482.6 mm (19 in.)
Weight: 34.9 kg (77 lb) to 50.4 kg
(111 lb) depending upon
configuration
Integrated functions:
Advanced System Management
Processor with Light Path
Diagnostics™
Dual-channel Ultra160 SCSI
controller non-RAID (one
internal and one external
channel)
One 10BASE-T/100BASE-TX
AMD Ethernet controller
Two serial ports
One parallel port
Two Universal Serial Bus ports
Keyboard port
Mouse port
Video port
Acoustical noise emissions:
Sound power, idling: 6.3 bel
maximum
Sound power, operating: 6.3 bel
maximum
Sound pressure, operating: 47
dBa maximum
Environment:
Air temperature:
Server on: 10° to 35° C (50º to
95º F). Altitude: 0 to 914 m
(3000 ft)
Server on: 10° to 32° C (50° to
89.6° F). Altitude: 914 m (3000
ft.) to 2133 m (7000 ft)
Server off: 10° to 43° C (50° to
110° F). Maximum altitude:
2133 m (7000 ft)
Humidity:
Server on: 8% to 80%
Server off: 8% to 80%
Heat output:
Approximate heat output in British
thermal units (Btu) per hour
Minimum configuration: 461 Btu
(0.14 kilowatts)
Maximum configuration: 1796 Btu
(0.53 kilowatts)
Electrical input:
Sine-wave input (50-60 Hz)
required
Input voltage low range:
Minimum: 90 V ac
Maximum: 137 V ac
Input voltage high range:
Minimum: 180 V ac
Maximum: 265 V ac
Input kilovolt-amperes (kVA)
approximately:
Minimum: 0.08 kVA
Maximum: 0.52 kVA

Advertisement

Table of Contents
loading

Table of Contents